Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:IS200EGDMH1A
GE IS200EGDMH1A Field Ground Detector Module EX2100
Manufacturer: General Electric
Product No.: IS200EGDMH1A
Product Type: Detector Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 540g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
General Electric IS200EGDMH1A EX2100 Exciter Ground Detector Module
The General Electric IS200EGDMH1A is an Exciter Ground Detector Module (EGDM) engineered for the EX2100 Excitation Control System series. Designed as a double-slot, double-height 6U form factor board, it mounts directly into the Exciter Power Backplane (EPBP) rack adjacent to the EPSM module. Operating across a wide temperature range of -30°C to +65°C, the IS200EGDMH1A works in tandem with the EXAM attenuator module to measure ground fault resistance between generator field circuits (AC/DC sides) and ground. Weighing just 1 lb 3 oz (0.54 kg), it supports both simplex (1 EGDM) and triple-redundant (3 EGDMs: C, M1, M2) configurations via high-speed fiber-optic links to the DSPX processor for automated signal conditioning and diagnostic alarms.
Technical Specifications
| Manufacturer & Series | General Electric (GE Energy) / EX2100 Series |
| Part Number & Acronym | IS200EGDMH1A (EGDM) |
| Product Type & Form Factor | Exciter Field Ground Detector Board | 6U Double Slot |
| Mounting Location | Exciter Power Backplane Rack (EPBP) |
| System Configuration | Simplex System (1 Module) / Redundant System (3 Modules) |
| Dimensions (H x D x W) | 9 in x 6 in x 1.5 in (Faceplate Width) |
| Operating Temperature | -30°C to +65°C (-22°F to +149°F) |
| Communication & Interface | Fiber-optic link to DSPX/EISB | EXAM Attenuator Interface |
| Faceplate LED Indicators | 3 LEDs: Power, Active, and Selected Master |
| Physical Weight | 1 lb 3 oz (approx. 0.54 kg) |
| Instruction Manual | GEI-100467 (GEH-6632 Series Manual) |
Quick Installation Guide
- Insert the IS200EGDMH1A into the designated double slot of the Exciter Power Backplane (EPBP) rack near the EPSM board.
- For triple-redundant control, ensure P2 connector program pins are configured correctly for Controller (C), Master 1 (M1), and Master 2 (M2) roles.
- Connect the fiber-optic transceivers to the EISB/DSPX controller rack and verify that Power, Active, and Selected Master LEDs illuminate correctly upon powering up.
Technical FAQs
Q1: What is IS200EGDMH1A's function?
A1: Detects EX2100 field ground leakage via EXAM attenuator signal conditioning.
Q2: Module counts per system type?
A2: Uses 1 module for simplex and 3 (C, M1, M2) for triple-redundant EX2100 systems.
Q3: How does it talk to DSPX board?
A3: Transmits voltage & diagnostic signals to DSPX via fiber-optic transceivers.
Ƙarin ƙayyadaddun bayanai
- Kore
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...
