Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:IC200UAL006
GE Fanuc IC200UAL006 VersaMax Micro Controller 120-240VAC
Manufacturer: General Electric
Product No.: IC200UAL006
Product Type: Controller Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The GE Fanuc IC200UAL006 is a compact Micro Programmable Logic Controller (PLC) from the VersaMax product line. Designed for small-to-medium industrial automation applications, this all-in-one controller integrates power supply, CPU, and I/O processing into a single robust unit.
Operating on a 120 to 240 V AC line voltage, the IC200UAL006 features 23 total I/O points (including both discrete and built-in analog signals) alongside two multi-protocol serial communication ports. Weighing 0.91 kg (2.00 lbs) with an estimated gross shipping weight of 1.20 kg (2.65 lbs), it provides an efficient, space-saving solution for distributed machine control.
Core Technical Advantages
- Versatile Hybrid I/O Mix: Combines 13 discrete inputs, 10 discrete outputs, 2 analog inputs, and 1 analog output within a single compact chassis.
- Dual Serial Communication Ports: Features Port 1 (RJ-45 RS-232) and Port 2 (DB-15 RS-485) for seamless programming, HMI connectivity, and network integration.
- Auxiliary Field Power Supply: Provides an onboard 24 V DC user sensor power supply rated at 200 mA to directly power field instrumentation.
- High Output Current Capacity: Built-in relay outputs support a maximum resistive load rating of 2 A at 240 V AC or 24 V DC for direct actuator driving.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | GE Fanuc |
| Part Number / Catalog No. | IC200UAL006 |
| Product Family | VersaMax Micro PLC |
| Product Type | Micro Programmable Logic Controller |
| Operating Voltage Rating | 120 V AC to 240 V AC |
| Total I/O Capacity | 23 Total I/O Points |
| Discrete Inputs / Outputs | 13 Discrete Inputs / 10 Discrete Relay Outputs |
| Analog Inputs / Outputs | 2 Analog Inputs / 1 Analog Output |
| Communication Ports | Port 1: RJ-45 (RS-232) | Port 2: DB-15 (RS-485) |
| User Sensor Power Output | 200 mA at 24 V DC |
| Max Relay Load Rating | 2 A at 240 V AC or 24 V DC (Resistive) |
| Portable Memory Support | Not Supported |
| Estimated Net / Shipping Weight | Net Unit: 0.91 kg (2.00 lbs) | Gross Shipping: 1.20 kg (2.65 lbs) |
Installation & Wiring Guidelines
- Power Supply Connection: Ensure input voltage line matches the required 120–240 V AC supply and is properly fused prior to energizing the PLC.
- Serial Port Assignment: Use the RJ-45 Port 1 for direct PC programming/configuration cables and DB-15 Port 2 for multi-drop RS-485 device networks.
- Sensor Auxiliary Power: Verify that total field sensor load connected to the internal 24 V DC auxiliary output does not exceed the 200 mA threshold.
Technical FAQs
Q1: How many total I/O points are built into the GE IC200UAL006?
A1: It features 23 total I/O points: 13 discrete inputs, 10 discrete outputs, 2 analog inputs, and 1 analog output.
Q2: What connectors are used for communication on this VersaMax Micro module?
A2: Port 1 uses an RJ-45 connector (RS-232), and Port 2 uses a DB-15 connector (RS-485).
Q3: Does the IC200UAL006 support portable memory modules?
A3: No, portable memory modules are not supported on this specific Micro PLC variant.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...
