Bayani

Technical Specifications

Part Number IC693MDL241
Product Type Discrete Input Module (AC / DC)
Brand / Manufacturer GE Fanuc / GE Intelligent Platforms
Product Series Series 90-30 PLC
Number of Inputs 16 Channels (Single isolated group with one common terminal)
Wiring Configuration Positive / Negative Logic (Sinking/Sourcing for DC mode)
Nominal Input Voltage 24 V AC / 24 V DC (50/60 Hz frequency for AC)
Input Voltage Range 0 to +30 V AC or 0 to +30 V DC
On-State Voltage / Current 11.5 to 30.0 V AC/DC / 3.2 mA minimum
Off-State Voltage / Current 0 to 4.0 V AC/DC / 1 mA maximum
Input Current Draw 7 mA per channel typical at rated nominal voltage
Backplane Power Draw 80 mA @ 5 V DC (All inputs ON); 125 mA from isolated 24 V DC bus
Signal Response Times Typical ON response: 12 ms / Maximum OFF response: 28 ms
Galvanic Isolation 1500 V RMS / 1500 V AC between field side and logic side
Net Product Weight 0.34 kg (Approx. 0.75 lbs)

Product Overview

The IC693MDL241 is a highly versatile 16-channel Discrete Input Module belonging to the globally deployed GE Fanuc Series 90-30 Programmable Logic Controller (PLC) architecture. Weighing a manageable 0.34 kg (0.75 lbs), this module provides exceptional deployment flexibility by processing either 24V AC or 24V DC field input signals within a single hardware block. Thanks to its smart dual-logic input design, it interfaces natively with positive or negative logic topologies (sinking or sourcing configurations) to safely monitor critical binary components including pushbuttons, electronic proximity switches, limit switches, and auxiliary relay contacts.

Core Technical Advantages

  • Flexible Multi-Voltage Compatibility: Accepts an extended operational range of 0 to 30 Volts in both alternating current (AC) and direct current (DC) configurations, reducing the necessity for separate module inventories.
  • Flexible Sinking and Sourcing Logic: Adapts directly to diverse user-supplied wiring logic topologies, matching positive or negative industrial control circuitry effortlessly in DC configurations.
  • High Galvanic Voltage Isolation: Integrates a strict 1500 V RMS optical separation path between the raw electrical field side and the sensitive internal CPU computing backplane, neutralizing noise spikes.
  • Detailed Real-Time Status Matrix: Incorporates two horizontal rows of eight sharp green LED indicators (labeled A1–A8 and B1–B8) to deliver clear visual diagnostics when active 7 mA field signals write a Logic 1 (%I) state to the CPU registry.

Installation Guide

De-energize the main power supply feeding the destination 5-slot or 10-slot Series 90-30 chassis prior to board insertion. Carefully align the rear connectors of the 0.34 kg IC693MDL241 along the upper and lower plastic channel tracks, pressing smoothly until the hardware security clips snap shut into the chassis rail. Route your 24V field circuits into the module's terminal block, connecting the common line appropriately to establish the preferred sinking or sourcing structure. The external loop can be powered directly via the PLC backplane's isolated 24V DC terminal or driven cleanly by an auxiliary external power supply array.

Technical FAQs

Q1: What are the exact voltage levels needed to guarantee an ON or OFF input state?
A1: To reliably trigger an active ON state (Logic 1), the field input must supply between 11.5 and 30.0 V AC/DC. Any residual signal dropped between 0 and 4.0 V AC/DC is read as an absolute OFF state (Logic 0).

Q2: Why does the documentation show two distinct 24V current draw figures?
A2: The module consumes 80 mA from the internal 5 V DC backplane to power its logic components when all points are active. The secondary 125 mA draw is pulled from the isolated 24 V DC bus (or an external field supply) to operate the optical isolation loops and input channel circuitry.

Q3: Does the 0.34 kg weight of this card require any additional reinforcement during vertical mounting?
A3: No. The light 0.34 kg physical footprint is securely held by the standard built-in slot hooks of the Series 90-30 baseplate framework, maintaining heavy vibration dampening in standard control panel environments.

🏷️ Tags: Discrete Input Module

Sikeli (V/f)

Vector

mai amfani da wutar AC

  • Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
  • Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
  • Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
  • Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
  • Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.

Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.

Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.

Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

Duba bayanin samfur

TABBTAR DA INGANTACCEN AIKIN NA'URORI

Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.