Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:FS-TSDO-0824
FS-TSDO-0824 Safety Output Module - Honeywell
Manufacturer: Honeywell
Product No.: FS-TSDO-0824
Product Type: Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Honeywell FS-TSDO-0824 Safe Digital Output FTA
The Honeywell FS-TSDO-0824 is a safe digital output FTA. It connects SICC-0001/Lx cables to field wiring. This module supports 8 channels from redundant SDO-0824 pairs.
Technical Specifications
- Brand & Model: Honeywell FS-TSDO-0824
- Alternative PN: FC-TSDO-0824
- Module Type: Safe Digital Output Field Termination Assembly
- Channel Count: 8 Channels
- Maximum Voltage: 36 V DC (IEC 1010 - 1990)
- Overvoltage Category: 3 (Table D.12)
- Current per Channel: 1.5 A maximum continuous
- Module Weight: Approximately 0.5kg
- Dimensions: 60 × 70 × 58 mm (2.36 × 2.76 × 2.28 in)
Terminal Specifications
- Termination Type: Screw Terminals
- Max Wire Diameter: 2.5 mm² (AWG 14)
- Strip Length: 7 mm (0.28 in)
- Tightening Torque: 0.5 Nm (0.37 ft-lb)
Mounting Specifications
- Mounting Type: Universal snap-in for DIN EN rails
- Compatible Rails: TS32 / TS35 × 7.5
- Required Rail Length: 61 mm (2.40 in)
- Installation: Standard DIN rail mounting
Environmental & Approvals
- Approvals: CE, TUV, UL, CSA, FM
- Safety Rating: Safe digital output applications
- Interface: SICC-0001/Lx system interconnection cable
- Compatibility: Redundant pairs of SDO-0824 modules
Frequently Asked Questions
How many channels does it support?
- 8 channels with 1.5A continuous current per channel. Maximum voltage 36V DC with overvoltage category 3 rating.
What wire size can it accept?
- Maximum 2.5 mm² (AWG 14) with 7mm strip length. Termination torque: 0.5 Nm for secure connections.
What are the dimensions and weight?
- Dimensions: 60 × 70 × 58 mm. Weight: approximately 0.18 kg (0.4 lb). Mounts on TS32/TS35 DIN rails with 61mm rail length required.
Ƙarin ƙayyadaddun bayanai
- Ruwan lemu
- Baƙi
- mai aiki da wutar DC
- Ƙarami
- Na sassa-sassa
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Do You Fix ControlLogix Redundancy Switchover Failures?
This article examines the hidden causes of Allen-Bradley 1756 redundant CPU switchover failures on oil and gas ski...
-
Why Is INFI90 End-of-Life a Growing Risk for Power DCS?
This article examines ABB Bailey INFI90 end-of-life risks in power DCS environments and presents a three-tier moderni...
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...