Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:FC-TSHART-1620M
FC-TSHART-1620M Honeywell Safe Input Module
Manufacturer: Honeywell
Product No.: FC-TSHART-1620M
Product Type: Analog Input FTA
Product Origin: USA
Payment:T/T, Western Union
Weight: 2000g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Honeywell TSHART-1620m Safe Analog Input FTA with HART
The Honeywell TSHART-1620m is a safe 16-channel interface module. It connects field sensors to the SAI-1620m safety analog input modules. This FTA supports 0-20mA signals and HART communication for hazardous Class I, Division 2 locations.
Technical Specifications
- Brand & Models: Honeywell, FS-TSHART-1620m, FC-TSHART-1620m
- Function: Safe 16-channel FTA with HART for SAI-1620m.
- Input Channels: 16 (2 groups of 8).
- Input Current: 0-25 mA.
- Input Resistance: 250 Ω (± 1%).
- Power Supply: 30 V DC external, 3 mA (no load).
- Output to SAI-1620m: 0-4 V DC, 0.10% accuracy.
- HART Interface: Compatible with MTL/P+F multiplexers.
- Fuse per Channel: 315 mA (SOC MQ2).
- Hazardous Area: Class I, Division 2 compliant.
- Dimensions: 250 × 70 × 60 mm / 9.84 × 2.76 × 2.36 in.
- Terminals: 2.5 mm² (AWG 14) max wire.
- Approvals: CE, TUV, UL, CSA, FM.
FAQ
-
Q: Does this module support HART communication?
A: Yes, the TSHART-1620m provides a HART interface. It enables connection to HART multiplexer units from MTL or Pepperl+Fuchs for device configuration and diagnostics. -
Q: What is the fuse rating for field transmitter protection?
A: Each channel includes a 315 mA fuse to provide overcurrent protection for connected field devices in compliance with safety requirements. -
Q: Can it be used in hazardous locations?
A: Yes, the TSHART-1620m is designed for Non-Incendive field circuits in Class I, Division 2 hazardous locations, with defined loop inductance/capacitance limits.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Do Default Bently Nevada Thresholds Trigger 71.8% Nuisance Alarms?
This technical article examines why factory-default Bently Nevada 3500 vibration thresholds frequently fail in real-w...
-
How to Optimize Spare Parts Sourcing for Honeywell Gas Detection?
This article presents a structured approach to sourcing Honeywell gas detection spares for industrial automation syst...
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
