Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:FC-TSAO-0220M
FC-TSAO-0220M Honeywell FTA fitar tashoshi 2
Manufacturer: Honeywell
Product No.: FC-TSAO-0220M
Product Type: Taron Haɗin Ƙarshe
Product Origin: USA
Payment:T/T, Western Union
Weight: 1200g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Takaitaccen Bayanin Samfuri
FC-TSAO-0220M module ne na Safe Analog Output Field Termination Assembly (FTA) mai babban aminci. Yana aiki a matsayin ƙaƙƙarfan mahadar tsakanin system interconnection cable (SICC-0001/Lx) da wayoyin filin na waje ta hanyar terminal na skur mai aminci. Yana tallafawa tashoshi biyu na 0(4)-20 mA analog output da aka keɓe, kuma wannan module ɗin yana sarrafa na'urorin filin kamar bawuloli da actuators a aikace-aikacen tsaro masu matuƙar muhimmanci (har zuwa SIL 3) da kuma waɗanda ba na tsaro ba a harkar masana'antar sarrafa aiki.
Manyan Fa'idodin Fasaha
- Keɓewa Mai Ƙarfi: Matosai na keɓewa da aka gina a ciki suna kare module ɗin SAO-0220M na sama daga kwararan wutar lantarki da sauye-sauyen wuta daga gefen filin har zuwa ma'aunin IEC 1010 Overvoltage Category 3.
- Ƙarfin Lod Mai Ƙarfi: Yana tallafawa mafi girman wutar 40 V DC da kuma ci gaba da yanzu na da'ira 25 mA a kowane tashar don tuƙa lod mai babban impedance a nisan dogaye.
- Haɗin Gas-Tight: Terminal na skur mai ɗaukar nauyi yana karɓar wayoyi har zuwa 2.5 mm² (AWG 14), yana hana wayoyi su sake saboda girgizar injinan masana'antu.
Ƙayyadaddun Bayanai na Fasaha
| Siga | Bayani na FC-TSAO-0220M | Bayani na FC-TSAOH-0220M |
|---|---|---|
| Tashoshi | Tashoshi 2 da aka keɓe gaba ɗaya | Tashoshi 2 tare da maida 0V ɗaya |
| Matsayin Siginar | 0-20 mA / 4-20 mA | 0-20 mA / 4-20 mA |
| Mafi Girman Wuta | 40 V DC | 40 V DC |
| Mafi Girman Ƙarfin Yanzu | 25 mA a kowane tashar | 25 mA a kowane tashar |
| Girman Waya | 2.5 mm² (AWG 14) | 2.5 mm² (AWG 14) |
| Girman Jiki | 50 × 70 × 48 mm | 64 × 109 × 66 mm |
| Amincewa | CE, TUV, UL, CSA, FM | CE, TUV, UL, CSA |
Shigarwa & Kula da Na'ura
- Haɗawa: A kafe shi a kan sandar DIN na daidaitaccen TS32 ko TS35 × 7.5. A ware tsawon 51 mm na sanda don module ɗin TSAO da 65 mm don nau'in TSAOH.
- Waya: A cire murfin wayoyin filin zuwa tsawon 7 mm daidai. Yi amfani da screwdriver mai auna karkacewa (torque) don matse skur na terminal zuwa 0.5 Nm (0.37 ft-lb).
- Shielding: A haɗa duk garkuwar wayoyin filin da ƙasa a farantin shigar kabad domin guje wa hayaniyar wuta a da'irar 4-20 mA.
Dalilin Zaɓar Wannan Module
- Bin Ka'idar SIL 3: An tabbatar da shi gaba ɗaya ta TUV, UL, CSA, da FM don amfani a muhimman tsarin Emergency Shutdown (ESD).
- Haɗin Kai na Asali: Yana haɗuwa daidai da dandalin Honeywell Safety Manager ta amfani da kebul na SICC-0001/Lx na daidaito.
- Gano Kuskure ta Atomatik: Yana tallafawa sa ido kan matsayin da'irar domin gano buɗaɗɗen da'ira da gajeriyar da'irar a filin nan take.
Tambayoyin Fasaha (FAQs)
Q1: Menene bambanci tsakanin FC-TSAO-0220M da FC-TSAOH-0220M?
A1: Nau'in TSAO na daidaito yana da tashoshi da aka keɓe gaba ɗaya kuma yana da ƙaramin girma (faɗin 50 mm), yayin da nau'in TSAOH ke raba maida 0V ɗaya kuma yana da faɗin jiki mafi girma (faɗin 64 mm).
Q2: Shin wannan na'urar tana tallafawa sa ido kan layi don gano matsalolin filin?
A2: Eh, idan an haɗa shi da na'urorin tsaron Honeywell, yana gano buɗe da gajeriyar kewayawa a cikin da'irar kulawa ta atomatik.
Q3: Shin wannan na'urar tana da aminci a shigar da ita a yankin da ke da haɗari?
A3: Eh. Yana da amincewar FM da CSA, wanda ke ba da damar shigar da shi cikin aminci a Muhalli Class I, Division 2 / Zone 2 idan an shigar da shi a cikin akwati mai dacewa.
Ƙarin ƙayyadaddun bayanai
- Ruwan lemu
- mai aiki da wutar DC
- Ƙarami
- Na sassa-sassa
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...
-
Standardised 3300 Probe Workflow Cuts False Trips by 90%?
Uncalibrated Bently Nevada 3300 probe replacements are responsible for 68% of false turbine trips, costing power plan...
-
Mixed GE Fanuc & ABB Servo Faults? Fix Heavy Lathe Downtime Now?
This guide presents a data-driven Standard Operating Procedure for diagnosing cross-brand motion control faults in he...
