Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:VFD4ABMS11ANSAA
Delta VFD4A8MS11ANSAA MS300 Drive
Manufacturer: Delta
Product No.: VFD4ABMS11ANSAA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 6350g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Delta VFD4A8MS11ANSAA – MS300 Series AC Drive
The Delta VFD4A8MS11ANSAA from the MS300 Series delivers reliable motor control for industrial applications. This 1 HP (0.75 KW) drive operates on 115V 1-phase power with a wide frequency range of 0–599 Hz. The VFD4A8MS11ANSAA offers both heavy duty and normal duty ratings for flexible application use.
- Model: VFD4A8MS11ANSAA
- Series: MS-300 Series
- Input Voltage – Phase: 115V – 1 Phase
- Motor Power Range: 1 HP – 0.75 KW
- Frequency: 0 – 599 Hz
- Frame Size: C1
- IP Level: IP20
- EMC Filter: Optional
Output ratings
- Heavy Duty Output: 4.8 A
- Normal Duty Output: 5.5 A
Physical specifications
- Weight: 2.80 lbs (1.27 kg)
- Dimensions (W x H x D): 3.43 in × 6.18 in × 5.98 in (87 mm × 157 mm × 152 mm)
- Protection Class: IP20
Key features
- Wide frequency range 0–599 Hz for versatile applications
- Heavy duty rating 4.8 A for demanding loads
- Normal duty rating 5.5 A for standard applications
- Compact C1 frame size for space-saving installation
- IP20 protection for indoor use
- Optional EMC filter for electromagnetic compliance
- 115V 1-phase input ideal for light industrial applications
Package contents
- One Delta VFD4A8MS11ANSAA MS300 Series drive
- Weight: 2.80 lbs (1.27 kg)
- Dimensions: 3.43 × 6.18 × 5.98 inches
- Shipping: FedEx, UPS, DHL
FAQs
Q: What is the power rating of VFD4A8MS11ANSAA?
A: It delivers 1 HP (0.75 KW) motor power with 115V 1-phase input.
Q: What are the output current ratings?
A: Heavy duty output is 4.8 A, normal duty output is 5.5 A.
Q: What frequency range does this drive support?
A: It supports 0–599 Hz for wide application flexibility.
Ƙarin ƙayyadaddun bayanai
- Baƙi
- Launin toka
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does ABB PLC Retrofit Cut Wastewater Plant Costs?
This article examines how ABB PLC retrofit projects modernize aging wastewater control systems. It presents field dat...
-
How Do Emerson Transmitters Improve Oilfield Measurement?
Emerson flow transmitters deliver reliable liquid measurement in harsh oilfield conditions where conventional meters ...
-
How Does a Safety PLC Protect Hazardous Chemical Zones?
This article explains why hazardous chemical and petrochemical sites require dedicated safety instrumented systems se...
-
How Do ABB Motor Protection Relays Cut Pump Station Risks?
ABB motor protection relays deliver millisecond-level current sampling and fast trip response for pump station motors...
-
How Does Bently Nevada 3500 Protect Centrifugal Compressors?
The Bently Nevada 3500 TSI platform delivers API 670-compliant vibration, axial displacement, and speed monitoring fo...
-
How Can Allen-Bradley HMI Retrofit Cut Factory Upgrade Costs by 60%?
Allen-Bradley HMI panel retrofit offers manufacturers a low-disruption path to modernize legacy PLC and DCS networks ...
