Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:3500/22-01-01-00
Bently Nevada Transient Data Interface 3500/22-01-01-00
Manufacturer: Bently Nevada
Product No.: 3500/22-01-01-00
Product Type: Transient Data Interface Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
3500-22-01-01-00 Bently Nevada Transient Data Interface – 288055-01 + 146031-01
The Bently Nevada 3500/22-01-01-00 is a Transient Data Interface for the 3500 Monitoring System. Includes TDI module (288055-01) with USB cable and 10Base-T/100Base-TX Ethernet I/O module (146031-01).
Product Information
| Manufacturer | Bently Nevada |
| Product Number | 3500/22-01-01-00 |
| Product Type | Transient Data Interface |
| TDI Module | 288055-01 (Standard with USB Cable) |
| I/O Module | 146031-01 (10Base-T/100Base-TX Ethernet) |
| Transient Data Interface Type | Standard (01) |
| I/O Module Type | 10Base-T/100Base-TX Ethernet (01) |
| Agency Approval | None (00) |
| Power Consumption | 10.5 Watts |
| Weight (Total) | 1.11 kg (TDI 0.91 kg + I/O 0.20 kg) |
| Dimensions (D x W x H) | 24.18 x 2.44 x 24.13 cm |
Technical Specifications
| Operating Temperature | -30°C to +65°C (-22°F to +149°F) |
| Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
| Humidity | 95% Non-Condensing |
| Battery Life (Powered) | 38 Years at 50°C (122°F) |
| Battery Life (Unpowered) | 12 Years at 50°C (122°F) |
| Communications | 10Base-T/100Base-TX Ethernet (RJ-45) |
| Front Panel | USB-B (Configuration Port) |
| OK Relay Rating | 5A @ 24 Vdc/120 Vac, 120W/600VA |
Features
- Combines RIM function with data collection capability
- 10Base-T/100Base-TX Ethernet communication
- USB-B front panel configuration port
- Supports steady state and transient dynamic waveform data
- OK relay indicates rack operating status
- Rack reset button for clearing latched alarms
- Address switch with 127 possible addresses
- Configuration keylock for RUN/PROGRAM modes
- Long battery life for extended operation
Installation Notes
- Installs in Slot 1 (adjacent to power supplies) of the 3500 rack
- When upgrading from RIM to TDI: Remove RIM, remove RIM I/O, insert TDI I/O, insert TDI
- USB cable (123M4610) required for isolation – computer must run on batteries to avoid ground loops
- Signal Common grounding: Use 2-pin connector, slide PIM switch to "HP" position
FAQs
Q1: What is the upgrade sequence from RIM to TDI?
A1: Remove RIM, remove RIM I/O, insert TDI I/O, insert TDI. Leaving RIM I/O in rack will damage the TDI.
Q2: What USB cable is required and why?
A2: Use 123M4610 USB cable. Computer must run on batteries to maintain isolation and avoid ground loops.
Q3: How to connect Signal Common to Instrument Ground?
A3: Use the 2-pin connector on I/O module. Slide the PIM switch toward "HP" to isolate Signal Common from chassis ground.
Product Documentation
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What is the Real Cost of Corrosion on Factory Automation?
Standard automation hardware fails rapidly in corrosive heavy industries, causing significant downtime and mainten...
-
Can DCS-PLC-TSI Synergy Cut Refinery Furnace Energy Loss by 7%?
This article explains how synchronizing Distributed Control Systems, Programmable Logic Controllers, and Turbine Supe...
-
How to Break Data Silos for Bently Nevada Cloud Integration?
This article examines standardized cloud integration for Bently Nevada System1 vibration monitoring across heter...
-
ABB DCS Hot Swap Guide for Multi-Brand Plants
This technical guide delivers quantified hot swap procedures for ABB DCS and multi-brand redundant control systems. B...
-
Best Practices for Integrating AB PLCs with Emerson DCS?
Field‑tested solutions for integrating Allen‑Bradley PLCs with Emerson DCS. Quantifies efficiency losses, analyzes pr...
-
Why Are Isolated Plant Monitoring Systems Still Failing in 2026?
Most process plants still operate disconnected monitoring and control systems, missing subtle mechanical faults that ...