Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:3500/33-01-01
Bently Nevada 3500/33-01-01 16-Channel Relay Module
Manufacturer: Bently Nevada
Product No.: 3500/33-01-01
Product Type: Relay Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 700g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Bently Nevada 3500/33-01-01 16-Channel Relay Module
Bently Nevada 3500/33-01-01 3500/33 16-Channel Relay Output Module. Provides 16 independent SPDT relay outputs for machinery protection systems. Epoxy-sealed relays with arc suppressors ensure reliable operation in demanding industrial environments. cNRTLus certified for Class I Division 2 hazardous areas.
Key Features
16 SPDT relay outputs. Epoxy-sealed environmental sealing. 250 Vrms arc suppressor standard. Four groups of four channels with switch-selectable Normally De-energized (ND) or Normally Energized (NE) operation. Front panel OK, TX/RX, and CH Alarm LEDs. 5.8W typical power consumption. Main module 0.7 kg, I/O module 0.4 kg.
Technical Specifications
| Manufacturer | Bently Nevada |
| Part Number | 3500/33-01-01 |
| Product Type | 3500/33 16-Channel Relay Module |
| Output Module (A) | 01 = 16-Channel Relay Output |
| Approval Option (B) | 01 = cNRTLus (Class I Division 2) |
| Power Consumption | 5.8 W typical |
| Relay Type | Single-pole Double-throw (SPDT) |
| Environmental Sealing | Epoxy-sealed |
| Arc Suppressor | 250 Vrms (standard) |
| Relay Contact Life | 10,000 cycles |
| Relay Operation | 4 groups of 4, switch-selectable ND/NE |
| Main Module Dimensions | 241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in) |
| Main Module Weight | 0.7 kg (1.6 lb) |
| I/O Module Dimensions | 241 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in) |
| I/O Module Weight | 0.4 kg (1.0 lb) |
| Rack Space (Main) | 1 full-height front slot |
| Rack Space (I/O) | 1 full-height rear slot |
| Origin | Made in U.S.A. |
Contact Ratings
Standard Relays
| Min Switched Current | 100 mA @ 5 Vdc |
| Max Switched Current | 5 A |
| Max Switched Voltage (DC) | 125 Vdc |
| Max Switched Voltage (AC) | 250 Vac |
| Max Switched Power (DC) | 70W @ 24Vdc, 10W @ 48Vdc, 9W @ 60Vdc |
| Max Switched Power (AC) | 1200 VA |
Failsafe / Hazardous Area Systems
| Min Switched Current | 100 mA @ 5 Vdc |
| Max Switched Current | 5 A |
| Max Switched Voltage | 30 Vdc |
Low Current Applications
| Min Switched Current | 1 mA @ 1 Vdc |
| Max Switched Current | 100 mA @ 48 Vdc |
Ordering Code Breakdown
3500/33-01-01
3500/33 – 16-Channel Relay Module.
A:01 – 16-Channel Relay Output Module.
B:01 – cNRTLus (Class I Division 2) hazardous area approval.
Installation Notes
Install main module in full-height front slot. Install I/O module in corresponding rear slot. Configure relay groups for ND or NE operation via switches. Observe contact rating limits for standard, failsafe, or low current applications. Ensure proper grounding per Bently Nevada guidelines.
Engineering Advantages
16 independent relay outputs provide flexible alarm and control signaling. Epoxy-sealed relays withstand harsh industrial environments. Arc suppressors extend contact life and reduce EMI. cNRTLus certification enables installation in Class I Division 2 hazardous areas. Switch-selectable ND/NE per group simplifies integration with existing control schemes.
FAQs
Q1: How many relay outputs does this module provide?
A1: 16 independent SPDT relay outputs.
Q2: What are the contact ratings for standard applications?
A2: 5A max, 125Vdc or 250Vac, 70W @ 24Vdc.
Q3: What is the relay operation configuration?
A3: Four groups of four channels, switch-selectable for Normally De-energized or Normally Energized operation.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...