Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:330103-00-16-10-12-CN
Bently Nevada 330103-00-16-10-12-CN | XL 8 mm FluidLoc Probe
Manufacturer: Bently Nevada
Product No.: 330103-00-16-10-12-CN
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Bently Nevada 330103-00-16-10-12-CN Proximity Probe
The 330103-00-16-10-12-CN (also cataloged as the 330103 3300 XL 8 mm Proximity Probe, Metric) provides radial vibration and axial position measurement in 3300 XL machinery monitoring systems. It has a PPS probe tip, an AISI 303/304 stainless steel case, an M10x1 thread, and a Miniature coaxial ClickLoc connector with FluidLoc cable at 1.0 m length. Probe cable weight is 323 g/m.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 330103-00-16-10-12-CN |
| Brand | Bently Nevada |
| Product Type | 3300 XL 8 mm Proximity Probe, Metric |
| Unthreaded Length | 0 mm |
| Overall Case Length | 160 mm |
| Total Length | 1.0 m (3.3 ft) |
| Connector | Miniature coaxial ClickLoc, FluidLoc cable |
| Agency Approval | CN (Country Specific) |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Case Material | AISI 303 or 304 stainless steel |
| Case Thread | M10x1, max. thread engagement 15 mm |
| Nominal Probe DC Resistance | 7.59 +/- 0.50 ohms at 1.0 m |
| Linear Range | 0.25 to 2.3 mm (10 to 90 mils), approx. -1 to -17 Vdc |
| Recommended Gap Setting | -9 Vdc [approx. 1.27 mm (50 mils)] |
| Operating Temp (Standard Probe) | -52 deg C to +177 deg C |
| Field Wiring | 0.2 to 1.5 mm2 (16 to 24 AWG), 3 conductor shielded triad, max. 305 m |
| Probe Weight | 323 g/m (11.4 oz/m) |
Field Installation Guidelines
Mount the probe in an M10x1 threaded hole with a maximum thread engagement of 15 mm. Confirm the 0 mm unthreaded length and 160 mm overall case length suit the machine housing bore. Set the radial vibration gap to -9 Vdc (approximately 1.27 mm or 50 mils) using a calibrated voltmeter before locking the probe. Route the 1.0 m FluidLoc ClickLoc cable and field extension through 3 conductor shielded triad cable, terminated with tinned conductors, with a total length not exceeding 305 m to the Proximitor Sensor. Ground the shield at the monitor end only. For hazardous area installation, verify the barrier or isolator matches drawing 141092 (ia) or drawing 140979 (nA) and confirm the area classification against the CN approval marking. Do not expose the probe to temperatures below -34 deg C to protect the pressure seal.
Frequently Asked Questions
Q: What is the recommended gap setting for radial vibration on the 330103-00-16-10-12-CN?
A: -9 Vdc, approximately 1.27 mm (50 mils).
Q: What is the nominal probe DC resistance at 1.0 m?
A: 7.59 +/- 0.50 ohms from center conductor to outer conductor.
Q: What is the maximum field wiring length between the Proximitor Sensor and the monitor?
A: 305 m (1000 ft) using 3 conductor shielded triad cable.
Ƙarin ƙayyadaddun bayanai
- Shuɗi
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...