Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:330101-00-27-50-02-00
Bently Nevada 3300 XL 8mm Probe | 330101-00-27-50-02-00
Manufacturer: Bently Nevada
Product No.: 330101-00-27-50-02-00
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Bently Nevada 330101-00-27-50-02-00 is a 3300 XL 8 mm proximity probe with 3/8-24 UNF thread, without armor. Designed for non-contact vibration and position measurement in turbomachinery, this probe delivers reliable performance with patented TipLoc and CableLoc technologies for enhanced durability.
Ordering Code Breakdown
330101 – 3300 XL 8 mm Probe, 3/8-24 UNF thread, without armor
00 – Unthreaded Length: 0.0 in
27 – Overall Case Length: 2.7 in (68.6 mm)
50 – Total Cable Length: 5.0 meters (16.4 ft)
02 – Connector: Miniature coaxial ClickLoc, standard cable
00 – No agency approval required
Technical Specifications
| Manufacturer | Bently Nevada |
| Model | 3300 XL 8 mm Probe |
| Part Number | 330101-00-27-50-02-00 |
| Thread Type | 3/8-24 UNF |
| Unthreaded Length | 00 – 0.0 in |
| Overall Case Length | 27 – 2.7 in (68.6 mm) |
| Total Cable Length | 50 – 5.0 m (16.4 ft) |
| Connector Type | Miniature coaxial ClickLoc |
| Linear Range | 0.25–2.3 mm (10–90 mils) / -1 to -17 Vdc |
| Recommended Gap (Radial) | -9 Vdc (approx. 1.27 mm / 50 mils) |
| Incremental Scale Factor | 7.87 V/mm (200 mV/mil) ±5% |
| Deviation from DSL (5m) | ±0.025 mm (±1 mil) @ 0°C–45°C |
| Probe DC Resistance (5m) | 8.73 ± 0.50 Ω |
| Extension Cable Capacitance | 69.9 pF/m (21.3 pF/ft) typical |
| Tip Material | Polyphenylene sulfide (PPS) |
| Case Material | AISI 303 or 304 stainless steel |
| Operating Temperature | -52°C to +177°C (-62°F to +350°F) |
| Storage Temperature | -52°C to +177°C (-62°F to +350°F) |
| Pressure Seal | Viton® O-ring |
| Humidity Test | 93% RH, 56 days (IEC 68-2-3) |
| Weight | 323 g/m (11.4 oz/m) approx. |
| Country of Origin | U.S.A. |
Installation Guide
Set initial probe gap to -9 Vdc (approx. 1.27 mm / 50 mils) for radial vibration applications. Torque to 12–15 N·m. Maintain minimum 50 mm bend radius for cable routing. For field wiring, use 0.2–1.5 mm² (16–24 AWG) 3-conductor shielded triad cable. Maximum field wiring length: 305 m (1,000 ft).
Engineering Advantages
Patented TipLoc molding provides robust bond between probe tip and body. CableLoc design delivers 330 N (75 lbf) pull strength. Thicker PPS encapsulation and larger diameter case offer superior durability against physical abuse. Optional FluidLoc prevents oil leakage through cable interior. Extended temperature range options available for high-temperature applications.
Technical FAQs
Q1: How to set the correct probe gap?
A1: Adjust the probe to achieve -9 Vdc output at the Proximitor sensor. This corresponds to the recommended 1.27 mm (50 mils) nominal gap for radial vibration measurements.
Q2: What is the maximum field wiring length?
A2: The maximum recommended field wiring length between the Proximitor sensor and the monitor is 305 meters (1,000 feet). Longer lengths may cause signal rolloff at high frequencies.
Q3: Can this probe be used in high-temperature environments?
A3: Standard probe supports -52°C to +177°C. For applications up to +218°C at the probe tip, order the Extended Temperature Range (ETR) option. Note: exposing the probe below -34°C may cause premature pressure seal failure.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...
-
Can Smart Gas Monitoring Cut False Alarms in Oil Facilities?
This article examines gas detection challenges in extreme oil and gas environments where legacy sensors show high dri...
-
Fixed Gas Detector or Transmitter – Which Protects Your Plant Better?
This technical article examines the critical operational differences between fixed gas detectors and gas detection tr...
-
What are real costs of fragmented brownfield control systems?
This article presents a production-focused data interconnection architecture that resolves multi-vendor control syste...
-
Can Compact PLCs Deliver Smart Benefits Without Shutdowns?
This technical article examines incremental smart retrofit strategies using Allen‑Bradley Compact control hardware fo...