Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:21000-28-10-30-018-04-02
Bently Nevada 21000-28-10-30-018-04-02 8mm Probe
Manufacturer: Bently Nevada
Product No.: 21000-28-10-30-018-04-02
Product Type: Housing Assembly
Product Origin: USA
Payment:T/T, Western Union
Weight: 1100g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Bently Nevada 21000-28-10-30-018-04-02 8mm Probe Assembly
The Bently Nevada 21000-28-10-30-018-04-02 is an 8 mm proximity probe assembly designed for turbomachinery monitoring. Featuring an aluminum body with a 304 stainless steel sleeve (2.5 mm thickness), this probe delivers reliable vibration and position measurements. Weighing 1.1 kg (2.4 lbs), it operates from -50°C to +80°C with IP67 dust/water resistance and CSA/ATEX Zone 1 certification.
Ordering Code Configuration
The 21000-28-10-30-018-04-02 part number follows this structure:
- 28 – 3300 XL 8 mm probe with CSA/ATEX Zone 1 certification
- 10 – 1.0 m high-flex polyurethane cable (bend radius: 25 mm)
- 30 – 3" standoff adapter (stainless steel 316L)
- 018 – 1.8 in (45.7 mm) probe penetration
- 04 – Dual-seal NPT plug (pressure rating: 500 psi)
- 02 – Configuration variant
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Bently Nevada |
| Model Number | 21000-28-10-30-018-04-02 |
| Probe Type | 8 mm Proximity Probe |
| Body Material | Aluminum with 304 SS sleeve (2.5 mm) |
| Weight | 1.1 kg (2.4 lbs) ±5% |
| Operating Temperature | -50°C to +80°C (-58°F to +176°F) |
| IP Rating | IP67 |
| Probe Penetration | 1.8 in (45.7 mm) ±0.1 mm |
| Cable Length | 1.0 m high-flex polyurethane |
| Cable Bend Radius | 25 mm |
| Standoff Adapter | 3" stainless steel 316L |
| Thread | 3/4-14 NPT (torque limit: 35 N·m) |
| Pressure Rating | 500 psi (dual-seal NPT plug) |
| O-ring Material | Fluorocarbon FKM (-20°C to +205°C) |
| Vibration Resistance | 15g peak (10-2000 Hz) |
| Certifications | CSA/ATEX Zone 1, CSA Type 4, RoHS, API 670 5th Edition |
Installation & Field Application Guide
- Install the probe using the 3/4-14 NPT thread. Torque to 35 N·m maximum to avoid thread damage.
- Ensure the dual-seal NPT plug is properly seated for 500 psi pressure rating.
- Route the high-flex polyurethane cable with a minimum bend radius of 25 mm.
- For hazardous area installations, verify compliance with CSA/ATEX Zone 1 requirements.
Why Choose the 21000-28-10-30-018-04-02
- CSA/ATEX Zone 1 certified for hazardous area installations.
- IP67 rating ensures protection against dust and water ingress.
- Wide temperature range (-50°C to +80°C) supports harsh environments.
- API 670 5th Edition compliance meets refinery and petrochemical standards.
Field Engineer FAQs
Q1: What is the difference between the 21000 and 3300 series probes?
A1: The 21000 series is a high-performance variant with enhanced materials (aluminum body, SS sleeve) and additional certifications such as API 670 compliance.
Q2: Can this probe be used in explosive atmospheres?
A2: Yes, the probe carries CSA/ATEX Zone 1 certification for use in explosive atmospheres with proper installation per hazardous area requirements.
Q3: What is the recommended gap voltage for this probe?
A3: The recommended gap setting for radial vibration is -9 VDC, corresponding to approximately 1.27 mm (50 mils).
Inquiries: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...