Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:22B-D010C104
Allen-Bradley PowerFlex 40 22B-D010C104 480V Drive
Manufacturer: Allen-Bradley
Product No.: 22B-D010C104
Product Type: AC Drive
Product Origin: USA
Payment:T/T, Western Union
Weight: 5000g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 22B-D010C104 PowerFlex 40 AC Drive
Product Overview
Allen-Bradley 22B-D010C104 is a PowerFlex 40 adjustable frequency AC drive. It delivers 5HP (4.0kW) output power at 10.5A. Operates on 480V AC 3 phase input. IP66 NEMA 4X enclosure for harsh environments. Features sensorless vector and V/F control with built in IGBT brake. Panel mount Frame B design with zero stacking capability.
Catalog Number Decoder
| Position | Code | Meaning |
|---|---|---|
| 1 3 | 22B | PowerFlex 40 |
| 4 | D | 480V AC 3 Phase |
| 5 | 010 | 10.5A Output (4.0kW / 5HP) |
| 6 | C | IP66 NEMA 4X Enclosure |
| 7 | 1 | Display/Fault Reset HIM |
| 8 | 0 | No EMC Filter |
| 9 | 4 | Standard Version |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 22B-D010C104 |
| Series | PowerFlex 40 |
| Output Power | 5 HP (4.0 kW) |
| Output Current | 10.5 A |
| Input Voltage | 480V AC 3 Phase |
| Output Voltage | 0 480V AC |
| Control Type | Sensorless Vector, V/F |
| Brake | IGBT included |
| Enclosure | IP66, NEMA 4X |
| Frame Size | B |
| Zero Stack | Yes |
| Dimensions H x W x D | 260 x 130 x 180 mm (10.24 x 5.12 x 7.09 in) |
| Operating Temperature | 0°C to +50°C |
| Altitude | 2000m max |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Weight | 5.0 kg (11.0 lbs) |
Installation
Switch off power before installation. Mount drive on panel cut out. Secure with M4 (#8-32) screws. Torque to 1.56 1.96 Nm. Connect 3 phase input to R/L1, S/L2, T/L3. Connect motor to U/T1, V/T2, W/T3. Connect RS485 cable to I/O terminals. Ground safety ground to PE terminal. Zero stacking permits side by side mounting without clearance. IP66 NEMA 4X enclosure suitable for washdown environments.
Wiring
Use copper wire only. Power terminals accept 5.3 mm² (10 AWG) max. I/O terminals accept 1.3 mm² (16 AWG) max. Separate control wiring from power wiring by 0.3m minimum. Remove MOV jumper for ungrounded distribution systems. For 4-20mA analog inputs, verify DIP switch settings match signal type.
Features
Sensorless vector control for high torque across full speed range. Built in IGBT brake for dynamic braking. IP66 NEMA 4X enclosure for harsh and washdown environments. Zero stacking reduces panel space. Supports RS485, ProfiBus, Ethernet, BACnet, Modbus, LonWorks. I/O includes 3 fixed, 4 programmable, 2 analog in, 1 analog out, 1 opto, 1 Form C relay.
FAQ
Q1: What is the difference between PowerFlex 40 and 40P?
A1: PowerFlex 40 is the base series (22B). PowerFlex 40P (22D) offers enhanced features including encoder feedback, position control, and additional I/O.
Q2: What does IP66 NEMA 4X enclosure mean?
A2: IP66 provides dust tight and high pressure water jet protection. NEMA 4X adds corrosion resistance for outdoor and washdown applications.
Q3: What is zero stacking?
A3: Zero stacking allows mounting drives side by side without clearance. Frame B drives require no spacing between drives, saving panel space.
Ƙarin ƙayyadaddun bayanai
- Baƙi
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
-
How to streamline industrial automation spare parts import clearance?
This guide delivers a data-driven framework for sourcing and clearing industrial automation spare parts, covering PLC...
-
How Fast Must DCS Switchover Be to Prevent Costly Process Upsets?
This article presents quantified DCS redundancy strategies using real 2024–2025 plant data. It details sub-100ms swit...
-
Why Is Explosion-Proof DCS Critical for Chemical Plant Safety?
This technical article examines how optimized multi-vendor explosion-proof DCS architectures address critical safety ...
-
How to restore Allen‑Bradley PLCs to 99.8% performance?
This technical article presents new, factory-original industrial automation hardware solutions for power plants and p...
