Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:25B-D6P0N114
Allen-Bradley 25B-D6P0N114 PowerFlex 525 VFD 3HP
Manufacturer: Allen-Bradley
Product No.: 25B-D6P0N114
Product Type: Variable Frequency Drive
Product Origin: USA
Payment:T/T, Western Union
Weight: 1300g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Allen-Bradley 25B-D6P0N114 is a PowerFlex 525 adjustable frequency AC drive delivering 2.2 kW (3.0 HP) motor output with 6.0 A rated current. Weighing approximately 1.3 kg, it operates on 323-528 VAC 3 phase input with 0-460 VAC output and an integral EMC filter.
Key Features
Integral EMC filter reduces external components and installation cost. Safe Torque Off (STO) functionality provides integrated safety. PointStop technology included. Built in HIM with start, stop, forward, reverse, and jog buttons plus potentiometer. Embedded Ethernet I/P and RS485 communication. Supports zero stacking at 45°C. Lightweight 1.3 kg Frame A design for DIN rail or panel mounting.
Technical Specifications
| Manufacturer | Rockwell Automation / Allen-Bradley |
| Part Number | 25B-D6P0N114 |
| Series | PowerFlex 525 Drive |
| Input Voltage | 323-528 VAC |
| Input Phase | 3 Phase |
| Output Voltage | 0-460 VAC |
| Output Current | 6.0 A |
| Output Power | 2.2 kW (3.0 HP) |
| Output Frequency | 0-500 Hz |
| Frame Size | Frame A |
| Enclosure Rating | IP20 / NEMA UL Type Open |
| EMC Filter | Integral |
| Safety | Safe Torque Off (STO) |
| Communication | Ethernet I/P, RS485 |
| Discrete Inputs | 7 Sink / Source |
| Discrete Outputs | 1 N.O., 1 N.C., 2 Digital Optocoupler |
| Analog Input | 2 (0-10VDC, 0-20mA) |
| Analog Output | 1 (0-10VDC, 0-20mA) |
| Control Methods | V/Hz, SVC, Closed Loop Vector, PM Motor |
| Dimensions | 6.77 x 2.83 x 5.98 inches |
| Weight | Approximately 1.3 kg |
Installation Guide
Mount the 25B-D6P0N114 (approx. 1.3 kg) on a standard DIN rail or screw mount to an enclosure subpanel. Connect 3 phase 323-528 VAC input and verify 6.0 A output current matches motor requirements. Use Ethernet I/P or RS485 for network integration with Studio 5000 Logix Designer. Zero stacking is supported at ambient temperatures up to 45°C. Ensure installation environment is dry and free from live current.
Engineering Advantages
Integrated EMC filter eliminates need for external filtering components. Safe Torque Off (STO) simplifies machine safety design without external contactors. Built in HIM with potentiometer and LCD enables local configuration and monitoring. Compact 1.3 kg Frame A footprint with zero stacking reduces panel size. Supports multiple motor control methods including permanent magnet motor control. Seamless integration with CompactLogix and ControlLogix via Ethernet I/P.
Frequently Asked Questions
Q1: What is the motor output rating of the 25B-D6P0N114?
A1: It delivers 2.2 kW (3.0 HP) with 6.0 A output current for both normal and heavy duty operation.
Q2: Does this drive include an EMC filter?
A2: Yes, it features an integral EMC filter, reducing external component requirements.
Q3: What safety functionality does this drive offer?
A3: It includes integrated Safe Torque Off (STO) functionality for machine safety applications.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
