Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:22F-RF025-BL
Allen-Bradley 22F-RF025-BL PowerFlex 4M EMC Filter Kit 25A
Manufacturer: Allen-Bradley
Product No.: 22F-RF025-BL
Product Type: Filter Kit
Product Origin: USA
Payment:T/T, Western Union
Weight: 1650g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 22F-RF025-BL PowerFlex 4M EMC Filter Kit
The Allen-Bradley 22F-RF025-BL is an EMC filter kit designed for PowerFlex 4M drives. This single-phase filter delivers 25A current handling for 100-120V AC or 200-240V AC input voltages. Featuring 35 dB insertion loss at 10 kHz with 4 mA leakage current, it ensures compliance with EMC emissions standards. Weighing 1.65 kg (3.64 lbs), it supports drives rated from 1.5 to 11 kW.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Allen-Bradley (Rockwell Automation) |
| Model Number | 22F-RF025-BL |
| Product Type | EMC Filter Kit |
| Series | PowerFlex 4M |
| Voltage | 100-120V AC or 200-240V AC |
| Current | 25A |
| Phase | Single-phase |
| Frequency | 50/60 Hz |
| Power Rating | 1.5 - 11 kW |
| Insertion Loss | 35 dB @ 10 kHz |
| Leakage Current | 4 mA maximum |
| Operating Temperature | -10°C to 60°C (14°F to 140°F) |
| Dimensions (L x W x H) | 180 x 80 x 65 mm (7.09 x 3.15 x 2.56 in) |
| Weight | 1.65 kg (3.64 lbs) |
Installation & Field Application Guide
- Mount the filter close to the drive input terminals to maximize EMI suppression effectiveness.
- Use shielded cables between the filter output and drive input. Keep cable runs as short as possible.
- Ensure the filter is properly grounded to the panel earth connection for optimal performance.
- Do not exceed 25A current rating. The filter is designed for single-phase systems only.
Why Choose the 22F-RF025-BL
- 35 dB insertion loss at 10 kHz ensures compliance with EMC standards.
- Supports drives from 1.5 to 11 kW, covering a wide range of applications.
- 4 mA leakage current meets safety requirements for residual current devices.
- Specifically designed for PowerFlex 4M drives for seamless integration.
Field Engineer FAQs
Q1: Is this filter required for CE compliance?
A1: Yes, the 22F-RF025-BL is required for CE compliance when installing PowerFlex 4M drives in the European market.
Q2: Can this filter be used with 3-phase systems?
A2: No, this filter is designed for single-phase systems only. For 3-phase applications, use the 22F-RF100-BL series.
Q3: What is the maximum cable length between filter and drive?
A3: Keep the cable length between filter output and drive input under 500 mm for optimal EMI suppression performance.
Inquiries: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...
-
How to Quantify and Fix Allen‑Bradley HMI Flickering in Cement Plants?
This technical article presents quantified field data from 2021–2026 on Allen‑Bradley HMI flickering in cement plants...
-
How to Fix HMI Flickering Caused by Power Noise and Vibration?
This article presents quantified field data from 2021–2026 on Allen‑Bradley HMI flickering faults in cement productio...