Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:22C-D6P0F103
Allen-Bradley 22C-D6P0F103 PowerFlex 400 Drive 3HP 6A 480V
Manufacturer: Allen-Bradley
Product No.: 22C-D6P0F103
Product Type: AC Drive
Product Origin: USA
Payment:T/T, Western Union
Weight: 4082g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 22C-D6P0F103 PowerFlex 400 AC Drive
The Allen-Bradley 22C-D6P0F103 is a compact PowerFlex 400 adjustable frequency AC drive optimized for fan and pump applications. Delivering 3 HP (2.2 kW) output at 6 A, it operates on 380-480 V AC three-phase input at 50-60 Hz. Featuring a flange mount IP20 enclosure in Frame Size C, this drive includes an integral control keypad and 7 digital inputs. Weighing 4.082 kg (9.0 lbs), it measures 260 x 130 x 180 mm.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Allen-Bradley (Rockwell Automation) |
| Part Number | 22C-D6P0F103 |
| Product Line | PowerFlex 400 |
| Drive Type | Fan & Pump |
| Input Voltage | 380-480 V AC, 3-Phase, 50-60 Hz |
| Output Current | 6 A |
| Output Power | 3 HP (2.2 kW) |
| Enclosure | Flange Mount IP20 |
| Frame Size | C (260 x 130 x 180 mm) |
| Dimensions (H x W x D) | 10.2 x 5.1 x 7.1 in (260 x 130 x 180 mm) |
| Weight | 4.082 kg (9.0 lbs) |
| Mounting | Flange Mount |
| Human Interface | Integral Control Keypad |
I/O Capabilities
| I/O Type | Quantity |
|---|---|
| Digital Inputs | 7 |
| Relay Outputs | 2 |
| Analog Inputs/Outputs | 2 |
| PTC Input | Optional |
Installation & Field Application Guide
- Professional installation required by qualified personnel only. The drive contains live electrical components that pose a shock hazard.
- Mount the 4.082 kg drive using flange mount configuration with adequate clearance for cooling.
- Size input fusing and wiring per local electrical codes for 6 A output.
- Configure fan and pump parameters via the integral keypad before operation.
Why Choose the 22C-D6P0F103
- Compact Frame Size C design saves panel space in HVAC and pump systems.
- Flange mount configuration enables efficient heat dissipation.
- Optimized for fan and pump applications with integral PID control.
- 7 digital inputs, 2 relay outputs, and 2 analog I/O provide flexible control.
Field Engineer FAQs
Q1: What is the recommended clearance around this flange mount drive?
A1: Maintain minimum 50 mm clearance on all sides for adequate airflow. The flange mount design allows heat to dissipate through the panel.
Q2: Can this drive control a motor with a PTC thermistor?
A2: Yes, the drive supports an optional PTC input for motor thermal protection when configured with the appropriate option module.
Q3: What is the maximum motor cable length for this 3 HP drive?
A3: For 480V drives, maximum motor cable length is 152 meters (500 feet) unshielded and 76 meters (250 feet) shielded.
Inquiries: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Can You Migrate ABB PLCs Without Stopping Production?
Aging ABB PLC platforms create rising reliability and spare-part risks for process plants. This article explains wher...
-
How Does Honeywell DCS Modernization Cut Refinery Downtime?
Honeywell DCS modernization helps refineries replace aging control hardware without full shutdowns. It tightens proce...
-
Why Do Hybrid DCS-PLC Systems Cause False Trips?
This article explains how to align Emerson DCS anti-surge control with ABB PLC compressor protection in hybrid ind...
-
How Can Brownfield Upgrades Modernize GE Fanuc DCS Visualization?
Aging GE Fanuc DCS visualization stacks create spare part delays, alarm chaos and unplanned downtime. This article ex...
-
Why Separate Safety PLC from GE Fanuc DCS?
Legacy GE Fanuc DCS platforms often merge process control with emergency trip logic, creating hidden risks durin...
-
How to Calibrate ABB PLC Signals for Emerson DCS Loops?
This article explains how to calibrate ABB PLC analog signals feeding Emerson DCS continuous process loops in hybrid ...