Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:22C-D010N103
Allen-Bradley 22C-D010N103 5HP Drive 0-400Hz PID
Manufacturer: Allen-Bradley
Product No.: 22C-D010N103
Product Type: Drive Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 3500g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 22C-D010N103 PowerFlex 400 AC Drive
The Allen-Bradley 22C-D010N103 is a PowerFlex 400 adjustable frequency AC drive designed for fan and pump control. Delivering 5 HP (3.7 kW) continuous duty output, it operates on 380-480 V AC three-phase input with 0-400 Hz adjustable output frequency. Featuring ±0.5% speed control accuracy and a built-in PID controller, this fan-cooled drive manages 1 main motor plus 3 auxiliary motors with AutoSwap function. Weighing approximately 3.5 kg (7.7 lbs), it operates from 0°C to 40°C.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Allen-Bradley (Rockwell Automation) |
| Part Number | 22C-D010N103 |
| Product Line | PowerFlex 400 |
| Output Power | 5 HP (3.7 kW) Continuous Duty |
| Input Voltage | 380-480 V AC, 3-Phase |
| Output Frequency | 0-400 Hz Adjustable |
| Control Accuracy | ±0.5% of Set Speed |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Cooling Method | Fan-Cooled with Thermal Protection |
| Weight | Approx. 3.5 kg (7.7 lbs) |
Advanced Motor Management
- Controls 1 main motor plus 3 auxiliary motors
- AutoSwap function rotates motor workloads for equal wear
- Built-in PID controller for pressure and flow control
- Motor interlock prevents dead zones in systems
- Automatic bypass for failed motors
Installation & Field Application Guide
- Panel mount the drive with minimum 10 mm clearance space for airflow.
- Use copper conductors only. Ground wire minimum 10 AWG required.
- A disconnect switch must be visible and accessible near the drive.
- Allow 30 minutes cool-down before servicing the drive.
Why Choose the 22C-D010N103
- Manages up to 4 motors (1 main + 3 auxiliary) for multi-pump systems.
- AutoSwap equalizes motor wear, extending equipment life.
- Built-in PID eliminates external controllers for pressure/flow regulation.
- 0-400 Hz adjustable output supports diverse fan and pump applications.
Field Engineer FAQs
Q1: How many motors can the 22C-D010N103 control?
A1: The drive controls 1 main motor plus up to 3 auxiliary motors, with AutoSwap rotating workloads to equalize wear across all connected motors.
Q2: What is the minimum clearance required for installation?
A2: Maintain a minimum of 10 mm clearance around the drive for adequate airflow and cooling.
Q3: What wire gauge is required for grounding?
A3: Use a minimum 10 AWG copper conductor for the ground wire to ensure proper safety grounding.
Inquiries: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does Honeywell SCADA Unify Multi-Site Manufacturing?
Honeywell SCADA enables manufacturers to unify monitoring across three to eight distributed plants while preserv...
-
How Do Eddy Current Probes Protect Rotating Machinery?
Bently Nevada eddy current proximity sensors deliver precise shaft displacement data for turbine and compressor prote...
-
How Can You Migrate ABB PLCs Without Stopping Production?
Aging ABB PLC platforms create rising reliability and spare-part risks for process plants. This article explains wher...
-
How Does Honeywell DCS Modernization Cut Refinery Downtime?
Honeywell DCS modernization helps refineries replace aging control hardware without full shutdowns. It tightens proce...
-
Why Do Hybrid DCS-PLC Systems Cause False Trips?
This article explains how to align Emerson DCS anti-surge control with ABB PLC compressor protection in hybrid ind...
-
How Can Brownfield Upgrades Modernize GE Fanuc DCS Visualization?
Aging GE Fanuc DCS visualization stacks create spare part delays, alarm chaos and unplanned downtime. This article ex...