Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1794-OM8
Allen-Bradley 1794-OM8 | Flex I/O Digital Output Module | 240VAC
Manufacturer: Allen-Bradley
Product No.: 1794-OM8
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Allen-Bradley 1794-OM8 is a Flex I/O digital AC output module with 8 nonisolated outputs. It operates at 240V AC nominal output voltage with a 4.0A output current rating. Weighing approximately 0.3 kg, the module fits inside the terminal bus, connecting field devices to the I/O bus. Modules can be inserted or removed under power since no direct wiring attaches to the I/O module, saving commissioning time and eliminating system restart inefficiency.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OM8 |
| Product Type | Flex I/O Digital Output Module |
| Outputs | 8 Nonisolated |
| Output Voltage Nominal | 240V AC (220V AC nominal on-state) |
| On-State Voltage Range | 159 to 264V AC |
| Output Current Rating | 4.0 A |
| On-State Current per Output | 500 mA maximum, 5 mA minimum at 55°C |
| On-State Voltage Drop | 1.5V AC @ 0.5A maximum |
| Off-State Leakage | 2.5 mA maximum |
| Isolation Voltage | 250V Continuous |
| Flexbus Current | 60 mA @ 5V DC |
| Power Dissipation | 5W @ 0.5A maximum |
| Thermal Dissipation | 17.1 BTU/hr @ 0.5A maximum |
| Weight | Approx. 0.3 kg |
| Compatible Terminal Bases | 1794-TBNF, 1794-TBN |
| Operating Temperature | 0 to 55°C (32 to 131°F) |
| Relative Humidity | 5 to 95% non-condensing |
| Mounting | DIN rail snap-on |
Installation Guide
Snap the module onto a DIN rail for mounting. Use the 1794-TBNF or 1794-TBN terminal base unit for field wiring connections. The module supports insertion and removal under power since no direct wiring attaches to the I/O module itself. Verify output loads do not exceed 500 mA per output or 4A per module. Confirm output voltage remains within the 159-264V AC on-state range. Maintain 0-55°C operating temperature and 5-95% non-condensing humidity.
Engineering Advantages
The 1794-OM8 supports hot-swap removal and insertion, eliminating system restart downtime during maintenance. Eight nonisolated outputs in a single module reduce panel space requirements. Multiple communication options (ControlNet, DeviceNet, EtherNet/IP, Universal Remote I/O) enable flexible network integration. The 250V continuous isolation rating protects the backplane. XT versions are available for extreme environment operation, reducing panel and maintenance costs.
Technical FAQs
Q1: How many outputs does the 1794-OM8 provide?
A1: This module includes 8 nonisolated AC outputs with 240V AC nominal voltage and 4.0A module current rating.
Q2: Can the module be removed while power is on?
A2: Yes, modules can be inserted or removed under power since the I/O module has no direct wiring, saving commissioning time.
Q3: What terminal base units are compatible?
A3: The 1794-OM8 works with the 1794-TBNF and 1794-TBN terminal base units for field device connections.
Ƙarin ƙayyadaddun bayanai
- Launin toka
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...
-
How Does Bently Nevada Balancing Stabilize Turbo Machinery?
This article explains how Bently Nevada TSI instruments enable practical field dynamic balancing for turbo machinery....
-
What Makes GE Historian Ideal for Industrial Time-Series Storage?
GE Historian delivers optimized long-term industrial time-series storage for control systems. It compresses OT data b...
-
How Do You Calibrate Honeywell Transmitters in Hazardous Areas?
This article explains how to calibrate Honeywell field instruments safely in hazardous areas, covering pre-calibratio...
-
How to Cut Bently Nevada TSI False Alarms on Compressor Skids?
This article explains how Bently Nevada TSI network layout affects compressor skid vibration monitoring reliability. ...
