Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1794-OB16P
Allen-Bradley 1794-OB16P Electronic Fused Output 24VDC
Manufacturer: Allen-Bradley
Product No.: 1794-OB16P
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 78g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1794-OB16P Flex I/O DC Fused Output Module
Allen-Bradley 1794-OB16P | Flex I/O discrete DC output module with 16 electronically fused sourcing output channels. Operates at 24V DC nominal voltage with 8.0 A total output current rating. Each channel provides electronic fusing for protection against overload conditions. Weight: approximately 78 g (2.75 oz).
Key Features
16 current sourcing outputs with electronic fusing. 24V DC nominal on-state voltage (10-31.2V DC range). 8.0 A total output current rating (500 mA per channel, 1 mA minimum). Maximum on-state voltage drop 0.5V DC. Maximum off-state leakage 0.5 mA. 50V continuous isolation voltage. Surge current 2 A for 50 ms, repeatable every 2 seconds. Output signal delay 0.5 ms (OFF-to-ON) and 1 ms (ON-to-OFF). 60 mA Flexbus current at 5V DC. 16 yellow status indicators. DIN rail mounting.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OB16P |
| Product Type | Flex I/O Digital DC Output Module |
| Outputs | 16 (Sourcing, electronically fused) |
| On-State Voltage (Nominal) | 24V DC |
| On-State Voltage (Min) | 10V DC |
| On-State Voltage (Max) | 31.2V DC |
| Output Current Rating | 8.0 A (total) |
| On-State Current (Min) | 1 mA per channel |
| On-State Current (Max) | 500 mA per channel |
| On-State Voltage Drop | 0.5V DC max |
| Off-State Leakage Current | 0.5 mA max |
| Isolation Voltage | 50V continuous |
| Surge Current | 2 A for 50 ms, repeatable every 2 s |
| Signal Delay (OFF-to-ON) | 0.5 ms |
| Signal Delay (ON-to-OFF) | 1 ms |
| Flexbus Current | 60 mA @ 5V DC |
| Power Dissipation | 5.0 W @ 31.2V DC |
| Thermal Dissipation | 17.0 BTU/hr @ 31.2V DC |
| External Power Supply | 10-31.2V DC, 5% AC ripple, 25-75 mA |
| Indicators | 16 Yellow status indicators |
| Mounting | DIN Rail |
| Wire Size | Determined by installed terminal base |
| Operating Temperature | 0°C to +55°C (32°F to 131°F) |
| Storage Temperature | -40°C to +85°C (-40°F to 185°F) |
| Relative Humidity | 5-95% non-condensing |
| Vibration | 5g @ 10-500 Hz |
| Operating Shock | 30 g |
| Weight | Approx. 78 g (2.75 oz) |
| UPC | 10612598179968 |
Compatible Terminal Base Units
1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK, 1794-TBN, 1794-TBNK, 1794-TBKD.
Installation Notes
Install on compatible terminal base with DIN rail attachment. Use screw clamp terminations for field wiring. Connect external DC supply of 10-31.2V DC with 5% AC ripple and 25-75 mA current. Compatible with ControlNet, DeviceNet, PROFIBUS, and EtherNet/IP communication adapters. Functions as distributed I/O for ControlLogix, CompactLogix, PLC5, and SLC500 controllers. Operate within 0°C to 55°C ambient temperature.
Engineering Advantages
Electronic fusing on each channel eliminates the need for replaceable fuses and simplifies maintenance. 16 sourcing outputs maximize channel density in a single module. High 8.0 A module rating handles demanding DC loads directly. Fast 0.5 ms OFF-to-ON response supports time-critical control applications. Wide 10-31.2V DC range accommodates supply variations. Compatible with multiple communication adapters and legacy controllers for flexible system integration.
FAQs
Q1: How many outputs does this module provide?
A1: 16 electronically fused sourcing DC outputs, 500 mA per channel.
Q2: What protection does each channel have?
A2: Each channel is electronically fused for overload protection.
Q3: What communication adapters are compatible?
A3: ControlNet, DeviceNet, PROFIBUS, and EtherNet/IP.
Ƙarin ƙayyadaddun bayanai
- Launin toka
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
