Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1794-OA8
Allen-Bradley 1794-OA8 Flex I/O AC Output Module
Manufacturer: Allen-Bradley
Product No.: 1794-OA8
Product Type: AC Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1794-OA8 Flex I/O AC Digital Output Module
Allen-Bradley 1794-OA8 | Flex I/O AC digital output module with 8 non-isolated output channels. Operates at 120V AC nominal voltage with 4.0 A output current rating. Designed for all non-hazardous industrial environments and Class 1, Division 2 areas. Weight: approximately 0.15 kg (0.33 lbs).
Key Features
8 non-isolated outputs in one group. 120V AC nominal output voltage, 85-132V AC range. 4.0 A output current rating. Minimum on-state current 5 mA per output. Maximum on-state voltage drop 1.0V at 0.5 A. Maximum off-state leakage 2.25 mA. 120V continuous isolation voltage. 80 mA Flexbus current at 5V DC. Surge current 7 A for 40 ms, repeatable every 8 seconds. Output signal delay max 1/2 cycle. Diagnostics for field devices, wiring, and power supply. Lightweight at 0.15 kg (0.33 lbs).
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OA8 |
| Product Type | Flex I/O Digital Output Module |
| Outputs | 8 (Non-isolated) |
| Output Voltage (Nominal) | 120V AC |
| Output Voltage Range | 85-132V AC |
| Output Current Rating | 4.0 A |
| On-State Current (Min) | 5 mA per output |
| On-State Voltage Drop | 1.0V max @ 0.5 A |
| Off-State Leakage Current | 2.25 mA max |
| Isolation Voltage | 120V continuous |
| Flexbus Current | 80 mA @ 5V DC |
| Surge Current | 7 A for 40 ms, repeatable every 8 s |
| Signal Delay (ON/OFF) | Max 1/2 cycle |
| Power Dissipation | 4.1 W @ 0.5 A; 6.3 W @ 0.75 A and 1 A |
| Thermal Dissipation | 14.0 BTU/hr @ 0.5 A; 21.2 BTU/hr @ 0.75 A; 21.4 BTU/hr @ 1 A |
| Weight | Approx. 0.15 kg (0.33 lbs) |
| UPC | 10612598137845 |
Current Derating by Temperature
| 55°C | 500 mA per output |
| 35°C | 750 mA per output |
| 30°C | 500 mA on 4 outputs; 1 A on 4 non-adjacent outputs |
Compatible Terminal Base Units
1794-TBNK, 1794-TBKD, 1794-TB3K, 1794-TBNFK, 1794-TB3SK, 1794-TBNF, 1794-TB3, 1794-TB2, 1794-TB3S, and 1794-TBN. Auxiliary terminal strips are required when using the 1794-TBN base unit.
Installation Notes
Install directly on compatible Flex I/O terminal base units. Use auxiliary terminal strips when mounting on the 1794-TBN base. Observe current derating based on ambient temperature: 500 mA per output at 55°C, 750 mA at 35°C. Verify off-state leakage does not affect connected loads. Ensure proper grounding per Allen-Bradley wiring guidelines. Suitable for non-hazardous and Class 1 Division 2 environments.
Engineering Advantages
Integrated diagnostics identify faults in field devices, wiring, and power supply, reducing commissioning and troubleshooting time. 8 outputs in a single Flex I/O module maximize channel density. High 4.0 A module rating handles demanding AC loads directly. Surge current capability of 7 A supports inductive load switching. Wide 85-132V AC range accommodates supply variations. Modular Flex I/O design enables flexible system expansion.
FAQs
Q1: How many outputs does this module provide?
A1: 8 non-isolated AC outputs in a single group.
Q2: What is the output voltage range?
A2: 85-132V AC, with a nominal rating of 120V AC.
Q3: What is the current rating at different temperatures?
A3: 500 mA per output at 55°C, 750 mA per output at 35°C, and 1 A on 4 non-adjacent outputs at 30°C.
Ƙarin ƙayyadaddun bayanai
- Launin toka
- Fari
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...