Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1794-IT8
Allen-Bradley 1794-IT8 | Flex I/O Thermocouple Input 8-Ch
Manufacturer: Allen-Bradley
Product No.: 1794-IT8
Product Type: DC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 250g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Allen-Bradley 1794-IT8 is an 8-channel Thermocouple/mV Analog Input Module for the Flex I/O system. It supports thermocouple types J, K, E, R, N, S, B, C, T, and L, plus ±76.5mV signals. With 16-bit resolution and 2.384 microvolt typical accuracy, it delivers precise temperature measurement in industrial applications.
Core Functionality
The 1794-IT8 interfaces directly with grounded or ungrounded thermocouples and millivolt transducers. It communicates with PLCs via block transfer programming, moving configuration words and input data between the module and the PLC data table. Two cold-junction compensators mount on the terminal base for accurate reference. The module requires key switch Position 3 on the terminal base for safe mounting.
Technical Specifications
| Parameter | Value |
| Part Number | 1794-IT8 |
| Series | Flex I/O |
| Module Type | Thermocouple/mV Input Module |
| Inputs | 8 channels |
| Thermocouple Types | J, K, E, R, N, S, B, C, T, L |
| Millivolt Range | ±76.5 mV |
| Resolution | 16-bit (2.384 µV typical) |
| Data Format | 16-bit 2's complement or offset binary |
| Isolation Voltage | 850V DC |
| Normal Mode Rejection | -60 dB at 60 Hz |
| Common Mode Rejection | -115 dB at 60 Hz / -100 dB at 50 Hz |
| Channel Bandwidth | 0 to 2.62 Hz |
| System Throughput | 325 ms |
| Flexbus Current | 20 mA |
| Power Dissipation | 3W max @ 31.2V |
| Thermal Dissipation | 10.2 BTU/hr @ 31.2V DC max |
| Terminal Base | 1794-TB2, -TB3, -TB3T |
| Keyswitch Position | 3 |
| CJC Unit Part Number | 969424-0 |
| Weight | Approx. 0.25 kg (0.55 lbs) |
Installation Guide
Rotate the terminal base keyswitch to Position 3 before inserting the 1794-IT8. Mount the two cold-junction compensators (969424-0) in their designated positions on the terminal base. Connect thermocouple or millivolt wiring, observing polarity for ±76.5mV inputs. Configure the module via block transfer programming in the PLC. Ensure 24V DC supply is connected. Supports both grounded and ungrounded thermocouples.
Engineering Advantages
This module supports 10 thermocouple types plus millivolt inputs for maximum application flexibility. 16-bit resolution with 2.384µV typical accuracy ensures precise temperature measurement. -115dB common mode rejection at 60Hz provides excellent noise immunity. 850V DC isolation protects the backplane. The dual cold-junction compensators maintain accurate reference compensation.
Technical FAQs
Q1: Supported thermocouple types and range?
A1: J, K, E, R, N, S, B, C, T, L plus ±76.5mV. Type B: 300-1800°C, Type K: -230 to 1372°C, Type J: -195 to 1200°C.
Q2: What terminal base and keyswitch position?
A2: Compatible with 1794-TB2, -TB3, -TB3T terminal bases. Keyswitch must be in Position 3 for safe mounting.
Q3: Resolution and isolation specs?
A3: 16-bit resolution (2.384µV typical). 850V DC isolation. Throughput 325ms. Flexbus current 20mA.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...
