Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1794-IF8IH
Allen-Bradley 1794-IF8IH 8-Channel HART Input Module Flex I/O
Manufacturer: Allen-Bradley
Product No.: 1794-IF8IH
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1794-IF8IH FLEX I/O HART Analog Input Module
The Allen-Bradley 1794-IF8IH is a FLEX I/O HART analog module featuring 8 isolated single-ended inputs. Using Sigma-Delta conversion with 16-bit unipolar and 15-bit bipolar resolution, this module provides reliable analog signal acquisition. Operating on 19.2 to 31.2 V DC, it consumes 4.8 W maximum. Weighing approximately 0.5 kg (1.1 lbs), it measures 3.7 x 3.7 x 2.6 inches and operates from 32°F to 131°F.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Part Number | 1794-IF8IH |
| Series | Flex I/O 1794 |
| Inputs | 8 (Isolated, single-ended) |
| Outputs | None |
| Conversion Type | Sigma-Delta |
| Unipolar Resolution | 16 bits |
| Bipolar Resolution | 15 bits plus sign |
| External DC Voltage | 19.2 to 31.2 V DC (5% AC ripple) |
| Flexbus Current | 80 mA @ 5 V DC |
| Power Dissipation | 4.8 W max @ 31.2 V DC |
| Thermal Dissipation | 16.4 BTU/hr @ 31.2 V DC |
| Operating Temperature | 32°F to 131°F (0°C to 55°C) |
| Enclosure | Open |
| Dimensions (W x H x D) | 3.7 x 3.7 x 2.6 in (94 x 94 x 66 mm) |
| Weight | Approx. 0.5 kg (1.1 lbs) |
| UPC | 10612598346902 |
Compatible Terminal Bases
- 1794-TB3
- 1794-TB3S
Installation & Field Application Guide
- Mount the module on a compatible terminal base (1794-TB3 or 1794-TB3S). Ensure secure seating.
- Use shielded wiring for signal connections. Signal ports are wiring category 2; power ports are wiring category 3.
- Verify external DC voltage is between 19.2 and 31.2 V DC with less than 5% AC ripple.
- Field calibration is available if factory calibration does not meet application requirements.
Why Choose the 1794-IF8IH
- 8 isolated HART analog inputs with Sigma-Delta conversion for high accuracy.
- 16-bit unipolar and 15-bit bipolar resolution for flexible signal measurement.
- North American Hazardous Location approval for safe operation in industrial environments.
- Field calibration capability allows in-situ adjustment without factory return.
Field Engineer FAQs
Q1: What is the difference between isolated and non-isolated inputs on this module?
A1: The 1794-IF8IH provides isolated inputs, meaning each channel is electrically separated from the module's backplane and other channels, reducing ground loop noise and protecting the system from field-side faults.
Q2: Can this module communicate HART data?
A2: Yes, the 1794-IF8IH supports HART communication, allowing access to device diagnostics and configuration parameters from connected HART field instruments.
Q3: What wire size should I use for the 1794-IF8IH?
A3: Wire size depends on the terminal base used. Refer to the terminal base documentation. Use shielded wiring for signal ports (category 2) and appropriate gauge for power ports (category 3).
Inquiries: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Do PLCs Turn Machine Data Into Proactive Risk Defense?
This article explores how Allen‑Bradley real‑time production monitoring mitigates hidden operational risks in disc...
-
Can Proper HMI Commissioning Really Cut Downtime by 54%?
This article examines the pivotal role of HMI visualization in industrial automation, drawing on field experience wit...
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
-
How Do Bently Nevada Transmitters Improve Bearing Health Monitoring?
This technical article examines the role of Bently Nevada vibration transmitters in industrial automation for ea...
-
What Are the Real ROI Gains of Upgrading Legacy Turbine Monitoring?
Operating legacy turbine supervisory instrumentation (TSI) beyond 12 years exposes power stations to false trips, pro...