Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1771-IFE
Allen-Bradley 1771-IFE PLC-5 Analog Input 16 Single 8 Diff
Manufacturer: Allen-Bradley
Product No.: 1771-IFE
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1771-IFE PLC-5 Analog Input Module
Allen-Bradley 1771-IFE is a PLC-5 analog input module with 16 single-ended or 8 differential channels. Supports voltage and current signals with 12-bit resolution, optoelectrical isolation, and digital filtering. Compatible with any 1771 I/O chassis.
Key Specifications
| Parameter | Value |
|---|---|
| Catalog No. | 1771-IFE |
| Series | PLC-5 |
| Module Type | Analog Input Module |
| Inputs | 16 single-ended or 8 differential |
| Resolution | 12-bit binary / 12 bits plus sign bipolar |
| Accuracy | 0.1% of full scale @ 25°C |
| Backplane Current | 750 mA |
| Max Power Dissipation | 2.5W |
| Weight | 0.5 kg |
Input Signal Ranges
| Signal Type | Range |
|---|---|
| Voltage | 1-5V, 0-5V, -5 to +5V, -10 to +10V, 0-10V DC |
| Current | 4-20mA, 0-20mA, -20 to +20mA |
Update & Scan Rate
| Parameter | Value |
|---|---|
| Channel Update (8 ch) | 18 ms |
| Channel Update (16 ch) | 36 ms |
| Internal Scan (8 diff) | 12.5 ms + 2.12 ms filtering |
| Internal Scan (16 SE) | 25 ms + 4.24 ms filtering |
Features
- Block transfer programming for PLC interface
- Optoelectrical isolation protects against electrical transients
- Input filtering reduces electrical noise
- Natural Binary or BCD scaling to ±9999
- Green RUN and red FAULT front panel indicators
- 1771-WG wiring arm allows module replacement without rewiring
- Keying bands between pins 10-12 (lower) and 24-26 (upper)
FAQs
Q1: How many input channels does the 1771-IFE have?
A1: 16 single-ended or 8 differential inputs.
Q2: What is the resolution?
A2: 12-bit binary or 12 bits plus sign on bipolar ranges.
Q3: What wiring arm is included?
A3: 1771-WG wiring arm.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...