Tsallake zuwa abun ciki
Kayan aikin sarrafa kansu, isarwa a ko’ina cikin duniya
Tsallaka zuwa bayanin kaya
1 na 3

SKU:1769-ASCII

Allen-Bradley 1769-ASCII | Dual Port ASCII Communication

A kan haja (16 guda), a shirye don aikawa
  • Manufacturer: Allen-Bradley

  • Product No.: 1769-ASCII

  • Product Type: Communication Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

Dokar Mayar da Kaya na Kwanaki 30 · Garantin Watanni 12
  • Isarwa Cikin Gaggawa
  • Tallafi na awa 24 a rana, kwana 7 a mako
  • Tabbacin Inganci

Bayani

Product Overview

The Allen-Bradley 1769-ASCII is a high-performance, dual-port serial communication module designed for the CompactLogix and MicroLogix 1500 platforms. This module enables seamless integration between your PLC and various ASCII-based devices, such as barcode scanners, weigh scales, serial printers, and legacy sensors. 

Technical Configuration & Hardware Architecture

The 1769-ASCII features a sophisticated hardware design that prioritizes signal purity and multi-protocol flexibility. It functions as an intelligent I/O module that resides directly on the 1769 backplane.

Dual Isolated Port Topology

Each port on the 1769-ASCII is electronically isolated to 30V continuous, protecting the backplane from ground loops and induced noise common in long-run serial cabling. Port 1 is optimized for RS-232 and RS-422 full-duplex communication, while Port 2 provides robust RS-485 multi-drop capabilities, allowing for versatile field device networking.

Backplane Integration

The module draws its 425mA operating current directly from the 5V DC backplane, simplifying enclosure wiring by eliminating the need for external power supplies. This hardware-level integration ensures that the communication ports are synchronized with the controller's internal clock for precise data time-stamping.

Technical Specifications

Feature Specification
Model Number 1769-ASCII
Number of Ports 2 Isolated Ports (DB-9 Male)
Protocols Supported RS-232, RS-422, RS-485
Max Baud Rate 115.2 kbps per port
Backplane Current Draw 425mA @ 5V DC
Operating Temperature 0°C to 60°C (32°F to 140°F)
Isolation Voltage 30V continuous (710V DC for 1s)

Installation & Engineering Guide

To ensure optimal performance of the 1769-ASCII, engineers must adhere to specific mechanical and electrical placement rules.

Power Supply Distance Rating

The 1769-ASCII has a power supply distance rating of 4. This means the module must be installed within four slots of the 1769 system power supply to ensure it receives consistent, regulated voltage for its dual-port circuitry.

Cabling and Grounding

For high-reliability data transmission, use high-quality shielded twisted-pair cabling (such as Belden 8761). Proper termination of the cable shield at the chassis ground is essential to minimize the impact of EMI on the ASCII string data, especially when operating at the maximum baud rate of 115.2 kbps.

Engineering Advantages

  • Simultaneous Communication: Both ports operate independently, allowing the system to read from a barcode scanner on Port 1 while sending data to a printer on Port 2.
  • Protocol Versatility: Native support for multiple RS-standards allows for easy retrofitting of legacy factory equipment into modern ControlLogix-based architectures.
  • Rugged Industrial Design: Capable of operating in high-temperature environments (up to 60°C) without the need for active cooling, provided that the 50mm clearance rule is followed.

Technical FAQs

Q1: Does the 1769-ASCII support Modbus RTU?
A1: While the module is hardware-capable of RS-485, it is primarily designed for raw ASCII string communication. Implementing Modbus RTU requires manual ladder logic programming to handle the Modbus frame and CRC checks.

Q2: Can I mix RS-232 and RS-485 on the same module?
A2: Yes. The 1769-ASCII ports are independent. You can configure Port 1 for RS-232 communication with a PC and Port 2 for an RS-485 network of sensors simultaneously.

Q3: Is external power required for the serial signal?
A3: No. The module generates the necessary signal voltages internally from the 5V backplane power. However, the connected device must provide its own power source for its communication interface.

🏷️ Tags: Communication Module

Sikeli (V/f)

Vector

mai amfani da wutar AC

  • Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
  • Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
  • Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
  • Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
  • Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.

Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.

Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.

Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

Duba bayanin samfur

TABBTAR DA INGANTACCEN AIKIN NA'URORI

Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.