Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1766-L32BWA
Allen-Bradley 1766-L32BWA Controller 20 Input 12 Relay
Manufacturer: Allen-Bradley
Product No.: 1766-L32BWA
Product Type: Controller Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 900g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1766-L32BWA MicroLogix 1400 Controller
Key Features
12 fast 24VDC inputs (100 kHz) plus 8 standard 24VDC inputs. 12 relay outputs (5-125VDC / 5-264VAC). 32 total digital I/O points. 20 KB user memory. Built-in real-time clock (RTC). Backlit LCD for network configuration and status monitoring. One isolated RS-232/485 combo port. One RS-232 port. One Ethernet port (10/100 Mbps). Supports up to 7 x 1762 expansion I/O modules. Up to 6 embedded 100 kHz high-speed counters. Panel or DIN rail mounting.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1766-L32BWA |
| Series | MicroLogix 1400 |
| Module Type | Controller |
| Number of I/O | 32 points |
| Inputs | 12 fast 24V DC + 8 standard 24V DC |
| Outputs | 12 (Relay) |
| Relay Output Operating Range | 5-125V DC; 5-264V AC |
| Memory | 20 KB |
| Operating Power | 110-240V AC |
| Power Consumption | 120 VA |
| Operating Frequency | 47-63 Hz |
| Inrush Current (120V) | 25 A for 8 ms |
| Inrush Current (240V) | 40 A for 4 ms |
| Communication Ports | 1 isolated RS-232/485 combo; 1 RS-232; 1 Ethernet |
| Serial Protocols | DF1, ASCII, Modbus RTU, DNP3, DH485 |
| Ethernet Protocols | EtherNet/IP, DNP3, Modbus TCP/IP |
| High-Speed Counters | Up to 6 x 100 kHz |
| Feature | Built-in Real-Time Clock (RTC), backlit LCD |
| Wire Size | 22 to 14 AWG |
| Cable Length | 30 m |
| Dimensions (H x W x D) | 90 x 180 x 87 mm (3.5 x 7.087 x 3.43 in) |
| Weight | Approx. 0.9 kg (2 lbs) |
| Mounting | Panel Mounting / DIN Rail |
| UPC | 10612598518101 |
Communication Interfaces
Isolated RS-232/485 combo port supports DF1, DH485, ASCII, DNP3 Serial, and Modbus RTU. RS-232 port supports programming and HMI connection. Ethernet port (10/100 Mbps) supports EtherNet/IP, DNP3 Ethernet, Modbus TCP/IP, embedded web server, and email capabilities. In Modbus RTU daisy-chain topology, up to 32 devices can be connected via RS-485.
FAQs
Q1: How many inputs and outputs does this controller have?
A1: 12 fast 24VDC inputs, 8 standard 24VDC inputs, and 12 relay outputs (32 total digital I/O points).
Q2: What communication protocols are supported?
A2: Serial: DF1, ASCII, Modbus RTU, DNP3, DH485. Ethernet: EtherNet/IP, DNP3, Modbus TCP/IP.
Q3: Can this controller be expanded?
A3: Yes, up to 7 x 1762 expansion I/O modules can be connected.
Ƙarin ƙayyadaddun bayanai
- Launin toka
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
-
What Makes Bently Nevada System 1 Essential for Predictive Maintenance?
Bently Nevada System 1 is a dedicated vibration analytics platform that pairs with 3500 TSI racks to deliver hig...
-
Is ABB MOD300 DCS Migration Still Worth the Investment?
ABB Advant MOD300 systems still run in many refineries and power plants, yet aging capacitors, scarce spares and hidd...
