Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1763-L16DWD
Allen-Bradley | 1763-L16DWD 12 DI 2 AI 6 Relay Output PLC
Manufacturer: Allen-Bradley
Product No.: 1763-L16DWD
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1763-L16DWD MicroLogix 1100 Programmable Controller
Product Overview
Allen-Bradley 1763-L16DWD is a MicroLogix 1100 programmable controller from the DC powered series. Features 10 standard discrete 12/24V DC inputs, 4 high speed input channels, 2 analog 0 to 10VDC inputs, and 6 relay outputs. Integrated RS232/485 combo port and Ethernet I/P port with built-in LCD display and keypad. Supports up to 4 MicroLogix 1762 expansion modules. Certified for Class 1 Division 2 hazardous locations.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1763-L16DWD |
| Series | MicroLogix 1100 |
| Type | Programmable Controller |
| Input Power | 12 to 24V DC |
| Power Consumption | 35 W |
| Inrush Current | 15 A |
| Point Count | 16 points |
| Digital Inputs | 10 x 12/24V DC sink/source |
| High Speed Inputs | 4 (channels 0 3) |
| Input Impedance | 3.1 kOhm nominal |
| Analog Inputs | 2 x 0 to 10VDC |
| Analog Resolution | 10 bit unsigned integer |
| Analog Impedance | 210 kOhm |
| Analog Overvoltage Protection | 10.5V DC |
| Relay Outputs | 6 x relay |
| Relay Voltage Range | 125V DC, 120 240V AC |
| Relay Response Time | 10 ms ON/OFF |
| Relay Mechanical Life | 10,000,000 cycles |
| Communication | RS232/485, Ethernet I/P |
| Protocols | DF1, DH485, Modbus, ASCII |
| Memory | Battery backed RAM |
| Display | LCD with keypad |
| Expansion Modules | Up to 4 (1762 series) |
| Operating Temperature | 20°C to +65°C |
| Shock Rating | 30 G 3 directional relay |
| Vibration Resistance | 1.5 G max |
| Hazardous Location | Class 1 Division 2 Groups A, B, C, D |
| Dimensions | 3.5 x 4.09 x 4.33 inches |
| Weight | 0.91 kg (2.0 lbs) |
| UPC | 10612598350787 |
Installation
Mount controller horizontally using DIN rail or direct panel mounting. Connect 12 to 24V DC power supply. Use 12 20 AWG solid wire or 14 20 AWG stranded wire for power and input wiring. Use Belden #8761 cable for analog channels with drain wire and foil shield connected to grounding system. Supports up to 4 MicroLogix 1762 expansion modules. Configure parameters via LCD and keypad or Ethernet port.
Features
10 discrete 12/24V DC sink/source inputs with 4 high speed channels. 2 analog 0 to 10VDC inputs with 10 bit resolution and 10.5V DC overvoltage protection. 6 relay outputs with 10 ms response time and 10,000,000 cycle mechanical life. Integrated RS232/485 combo port and Ethernet I/P. Supports DF1, DH485, Modbus, and ASCII protocols. Battery backed RAM. LCD with keypad for data monitoring. Class 1 Division 2 hazardous location certified.
FAQ
Q1: How many I/O points does this controller have?
A1: 16 points: 10 standard discrete 12/24V DC inputs, 4 high speed input channels, 2 analog 0 to 10VDC inputs, and 6 relay outputs.
Q2: What communication protocols are supported?
A2: RS232 supports DF1, DH485, Modbus, and ASCII protocols. Ethernet I/P port for networked communication. Both ports support HMI and SCADA connections.
Q3: What expansion capability does this controller support?
A3: Supports up to 4 MicroLogix 1762 expansion modules. Certified for Class 1 Division 2 hazardous locations Groups A, B, C, D.
Ƙarin ƙayyadaddun bayanai
- Launin toka
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
-
What Makes Bently Nevada System 1 Essential for Predictive Maintenance?
Bently Nevada System 1 is a dedicated vibration analytics platform that pairs with 3500 TSI racks to deliver hig...
-
Is ABB MOD300 DCS Migration Still Worth the Investment?
ABB Advant MOD300 systems still run in many refineries and power plants, yet aging capacitors, scarce spares and hidd...