Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1763-L16BBB
Allen-Bradley 1763-L16BBB 10 DI 2 AI 2 Relay 4 FET Controller
Manufacturer: Allen-Bradley
Product No.: 1763-L16BBB
Product Type: Controller Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1020g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1763-L16BBB MicroLogix 1100 Programmable Controller
Product Overview
Allen-Bradley 1763-L16BBB is a MicroLogix 1100 programmable controller powered by external 24V DC supply. Features 10 discrete 24V DC inputs, 2 analog 0 to 10VDC inputs, 2 relay outputs, and 4 FET outputs. Includes 4 high speed input channels at 0 to 40 kHz. Integrated RS232 and Ethernet communication ports with built-in LCD display. Certified for Class 1 Division 2 hazardous locations.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1763-L16BBB |
| Series | MicroLogix 1100 |
| Type | Programmable Controller |
| Input Power | 24V DC (15%, +10%) Class 2 SELV |
| Power Consumption | 35 W |
| Point Count | 16 points |
| Digital Inputs | 10 x 24V DC (4 high speed) |
| High Speed Inputs | 0 to 40 kHz (channels 0 3) |
| Standard Inputs | 0 to 1 kHz (inputs 4 10) |
| Analog Inputs | 2 x 0 to 10VDC |
| Analog Resolution | 10 bit unsigned integer |
| Analog Accuracy | ±0.5% full scale |
| Relay Outputs | 2 x isolated |
| Relay Voltage | 125V DC (1.0A), 120/240V AC (2.5A) |
| FET Outputs | 4 x 24V DC |
| Communication | RS232/485, Ethernet 10/100 Mbps |
| Protocols | DF1, Modbus, EtherNet/IP |
| Display | LCD |
| Operating Temperature | 20°C to +65°C |
| Vibration Resistance | 1.5 G |
| Shock Rating | 30 G 3 directional relay |
| Hazardous Location | Class 1 Division 2 Groups A, B, C, D |
| Dimensions | 3.5 x 4.33 x 3.43 inches |
| Weight | 1.02 kg (2.25 lbs) |
| UPC | 10662074023049 |
Installation
Mount controller in industrial enclosure for environmental protection. Connect 24V DC external supply (Class 2 SELV). Wire discrete inputs at 14 to 26.4V DC at 65°C or 14 to 30V DC at 30°C. Connect analog devices to 0 to 10VDC inputs. Configure communication via RS232/485 combo port or Ethernet. Set parameters using built-in LCD display. Certified for Class 1 Division 2 hazardous locations.
Features
10 discrete 24V DC inputs with 4 high speed channels up to 40 kHz. 2 analog 0 to 10VDC inputs with 10 bit resolution and ±0.5% accuracy. 2 relay outputs and 4 FET outputs at 24V DC. Integrated RS232/485 and Ethernet 10/100 Mbps. Supports DF1, Modbus, and EtherNet/IP protocols. Built in LCD for data monitoring and configuration. Class 1 Division 2 hazardous location certified. Vibration resistance 1.5 G and shock rating 30 G.
FAQ
Q1: What is the power supply requirement?
A1: External 24V DC supply (15%, +10%) Class 2 SELV. Power consumption 35W.
Q2: How many high speed inputs does this controller have?
A2: 4 high speed input channels located at channels 0 3 with switching frequency 0 to 40 kHz. Inputs 4 to 10 are standard DC inputs at 0 to 1 kHz.
Q3: What are the output ratings?
A3: 2 relay outputs at 125V DC (1.0A) or 120/240V AC (2.5A). 4 FET outputs at 24V DC. Hazardous location relay load 360V/3A, non hazardous 720VA/5A.
Ƙarin ƙayyadaddun bayanai
- Launin toka
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...