Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1762-OX6I
Allen-Bradley 1762-OX6I MicroLogix Isolated Relay Module
Manufacturer: Allen-Bradley
Product No.: 1762-OX6I
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 220g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1762-OX6I MicroLogix Isolated Relay Output Module
Allen-Bradley 1762-OX6I | MicroLogix 1200 series isolated relay output expansion module with 6 individually isolated Form C contact outputs. Compatible with MicroLogix 1100, 1200, and 1400 controllers. Each output provides one Normally Open and one Normally Closed terminal for flexible switching. DIN rail or panel mounting. Weight: approximately 220 g (0.485 pounds).
Key Features
6 individually isolated Form C relay outputs. Operating voltage range 5-125VDC and 5-265VAC. 7 A continuous current per point. 10 ms maximum ON signal delay, 20 ms maximum OFF delay. 110 mA bus current draw at 5VDC and 24VDC. 6 isolated groups (outputs 0-5). Flat ribbon cable with female bus connector. Power supply distance rating 6. Requires 2-inch clearance on all sides for airflow. Compatible with MicroLogix 1100/1200/1400.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1762-OX6I |
| Product Family | MicroLogix 1200 |
| Product Type | Discrete Output Module |
| No. of Outputs | 6 (Isolated Relay) |
| No. of Groups | 6 (individually isolated) |
| Output Form | Type C Relay (1 N.O. + 1 N.C.) |
| Output Voltage Range | 5-125V DC; 120/240V AC |
| Operating Voltage Range | 5-264V AC; 5-125V DC |
| Voltage Category | AC/DC Type |
| Continuous Current per Point | 7 A |
| Signal Delay (ON) | 10 ms max (6 ms typical) |
| Signal Delay (OFF) | 20 ms max (12 ms typical) |
| Bus Current Draw | 110 mA @ 5V DC; 110 mA @ 24V DC |
| Power Supply Distance Rating | 6 |
| Compatible Controllers | MicroLogix 1100 / 1200 / 1400 |
| Mounting Type | DIN Rail or Panel Mount |
| Connection | Flat ribbon cable with female bus connector |
| Dimensions (H x W x D) | 90 x 40.4 x 87 mm (3.54 x 1.59 x 3.43 in) |
| Weight | Approx. 220 g (0.485 lbs) |
| Operating Temperature | 0°C to +55°C (32°F to 131°F) |
| Maximum Altitude | 2000 m (6561 ft) |
Installation Notes
Leave 2-inch (50.8 mm) clearance on all sides of the module for proper airflow and to prevent overheating. Mount on DIN rail with end anchors, or use two Panhead screws per module for high-vibration environments. Connect to the controller and adjacent I/O modules using a flat ribbon cable with female bus connector. Up to 4 modules can be used with MicroLogix 1100, 6 with MicroLogix 1200, and 7 with MicroLogix 1400.
Engineering Advantages
Individually isolated Form C relays allow each channel to switch independent circuits, simplifying mixed-voltage installations. High 7 A per point rating handles demanding loads directly without interposing relays. Form C contacts provide both normally open and normally closed options on every channel. Dual AC/DC voltage capability eliminates the need for separate output module types. Compact 220 g design with flexible mounting options simplifies panel layout.
FAQs
Q1: How many outputs does this module provide?
A1: 6 individually isolated Form C relay outputs.
Q2: What is the maximum current per point?
A2: 7 A continuous current per point.
Q3: How many modules can be connected to each controller?
A3: Up to 4 with MicroLogix 1100, 6 with MicroLogix 1200, and 7 with MicroLogix 1400.
Ƙarin ƙayyadaddun bayanai
- Launin toka
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Makes Siemens PCS 7 AS410 Ideal for Chemical DCS?
Siemens PCS 7 with the AS410 automation station delivers high availability for continuous chemical manufacturing. Thi...
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...