Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1762-OW16
Allen-Bradley 1762-OW16 MicroLogix 16 Relay Output
Manufacturer: Allen-Bradley
Product No.: 1762-OW16
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 286g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1762-OW16 MicroLogix Relay Output Module
Allen-Bradley 1762-OW16 | MicroLogix relay output expansion module with 16 relay output channels. Compatible with MicroLogix 1100, 1200, and 1400 controllers. Provides AC and DC load switching capability for industrial automation applications. DIN rail or panel mounting. Weight: approximately 286 g (0.63 pounds).
Key Features
16 relay outputs in 2 isolated groups of 8 channels each. Operating voltage range 5-265V AC and 5-125V DC. 10 ms signal delay for ON/OFF transitions. 2.5 A maximum current per point. 8 A continuous current per common. 16 A continuous current per module. 1440 VA maximum controlled load. 6.1 W heat dissipation. IP20 enclosure rating. DIN rail or panel mounting. Surge suppressors recommended for inductive loads.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1762-OW16 |
| Series | MicroLogix |
| Module Type | Relay Output Module |
| Compatible Controllers | MicroLogix 1100 / 1200 / 1400 |
| Outputs | 16 (AC/DC Relay) |
| Isolated Groups | 2 (8 channels per group) |
| Relay Contact Voltage Ratings | 24-125V DC; 120-240V AC |
| Operating Voltage Range | 5-265V AC; 5-125V DC |
| Signal Delay | 10 ms |
| Max Current per Point | 2.5 A |
| Continuous Current per Common | 8 A |
| Continuous Current per Module | 16 A |
| Maximum Controlled Load | 1440 VA |
| Minimum On-State Current | 10 mA |
| Bus Current Draw | 140 mA @ 5V DC; 180 mA @ 24V DC |
| Heat Dissipation | 6.1 W |
| Enclosure Rating | IP20 |
| Mounting Type | DIN Rail; Panel Mounting |
| Dimensions (H x W x D) | 90 x 40.4 x 87 mm (3.54 x 1.59 x 3.43 in) |
| Weight | Approx. 286 g (0.63 lbs) |
| UPC | 10611320152149 |
Installation Notes
Mount on DIN rail or panel as required by the base controller. Install surge suppressors across inductive loads to extend relay contact life. Maintain proper grounding to limit electrical noise. Up to 4 modules can be used with MicroLogix 1100, 6 modules with MicroLogix 1200, and 7 modules with MicroLogix 1500. Take precautions against electrostatic discharge, which can damage internal semiconductors. Keep the module in an IP20 enclosure.
Engineering Advantages
Dual AC/DC load capability eliminates the need for separate output modules. Two isolated groups of 8 channels provide flexibility in wiring and fault isolation. High 2.5 A per point rating handles demanding industrial loads directly. 10 ms signal delay supports responsive control applications. Expandable up to 7 modules with MicroLogix 1500 for large I/O counts. Compact 286 g design with DIN rail mounting simplifies panel layout.
FAQs
Q1: How many outputs does this module provide?
A1: 16 relay outputs in 2 isolated groups of 8 channels each.
Q2: What is the maximum current per point?
A2: 2.5 A per point, with 8 A per common and 16 A per module.
Q3: How many modules can be connected to each controller?
A3: Up to 4 with MicroLogix 1100, 6 with MicroLogix 1200, and 7 with MicroLogix 1500.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...
