Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1762-OA8
Allen-Bradley 1762-OA8 Solid-State Output Module 8 Point AC Triac
Manufacturer: Allen-Bradley
Product No.: 1762-OA8
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 230g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1762-OA8 Solid-State AC Output Module
The Allen-Bradley 1762-OA8 is an 8-point solid-state AC output module for MicroLogix 1100, 1200, and 1400 systems. Featuring AC triac outputs, it operates from 85 to 265 V AC at 47 to 63 Hz with 100 to 240 V AC input power. With 2 commons, 115 mA maximum bus current at 5 V DC, and 2.9 W heat dissipation, this module delivers reliable switching for AC loads. Weighing 0.5 lbs (0.23 kg), it operates from 32°F to 131°F.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1762-OA8 |
| Function | Solid-State Output Module |
| Outputs | 8 (AC Triac) |
| Input Power | 100 to 240 V AC |
| Operating Voltage | 85 to 265 V AC |
| Operating Frequency | 47 to 63 Hz |
| Commons | 2 |
| Maximum Bus Current | 115 mA @ 5 V DC |
| Max Voltage Drop | 1.5 V @ 0.5 A |
| Minimum On-State Current | 10 mA |
| Heat Dissipation | 2.9 W |
| Dimensions (H x W x D) | 3.54 x 1.59 x 3.43 in (90 x 40 x 87 mm) |
| Shipping Weight | 0.5 lbs (0.23 kg) |
| Operating Temperature | 32°F to 131°F (0°C to 55°C) |
| Non-Operating Temperature | -40°F to 185°F (-40°C to 85°C) |
| Standards | NEMA ICS 2-230, EN50081-2 Class A, IEC1000-4-2, IEC1000-4-3 |
Installation & Field Application Guide
- Mount the 0.5 lb module on a proper grounded surface such as a metal panel. Refer to Allen-Bradley wiring and grounding guidelines.
- Ensure the module is free of all metal fragments before applying power. Fragments can cause damage during operation.
- Keep the finger-safe cover in place when wiring the terminal block. Once removed, the cover cannot be reinstalled due to wire positions.
- Verify minimum on-state current of 10 mA for reliable triac triggering.
Why Choose the 1762-OA8
- 8 AC triac outputs directly drive 100-240 V AC loads without external relays.
- Compatible with MicroLogix 1100, 1200, and 1400 controllers.
- Low heat dissipation (2.9 W) reduces panel cooling requirements.
- Meets NEMA, EN, and IEC standards for industrial noise immunity.
Field Engineer FAQs
Q1: What is the minimum load current for the 1762-OA8 outputs?
A1: The minimum on-state current is 10 mA. Loads below this threshold may not trigger the triac reliably; install a bleed resistor if needed.
Q2: Can the finger-safe cover be reinstalled after wiring?
A2: No. Once removed, the wires prevent the cover from being put back on the module. Plan wiring carefully before removal.
Q3: Which MicroLogix controllers are compatible with this module?
A3: The 1762-OA8 is compatible with MicroLogix 1100, MicroLogix 1200, and MicroLogix 1400 systems.
Inquiries: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...