Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1762-L24AWAR
Allen-Bradley 1762-L24AWAR PLC 14 Input 10 Relay
Manufacturer: Allen-Bradley
Product No.: 1762-L24AWAR
Product Type: Controller Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 900g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1762-L24AWAR MicroLogix 1200 PLC
Allen-Bradley 1762-L24AWAR | MicroLogix 1200 sinking and sourcing Programmable Logic Controller with 14 AC inputs and 10 relay outputs. Features a dedicated RS-232 Programmer/HMI port for DH Full-Duplex communication. Powered by external 120/240VAC nominal supply. Mounting dimensions: 3.5 x 4.33 x 3.43 inches. Weight: approximately 0.9 kg (2.0 lbs).
Key Features
14 digital inputs (120VAC). 10 relay outputs. RS-232 Programmer/HMI port (DH Full-Duplex). 120/240VAC input power. 47-63 Hz operating frequency. On-state voltage 79-132VAC. Off-state voltage 0-20VAC. Off-state leakage 2.5 mA max. Five isolation voltage groups. 400 mA at 5VDC / 350 mA at 24VDC backplane output. Compact DIN rail mount design. Lightweight at 0.9 kg (2.0 lbs).
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1762-L24AWAR |
| Product Line | MicroLogix 1200 |
| Module Type | Sinking / Sourcing Controller |
| Input Power | 120-240V AC |
| No. of Inputs | 14 (120V AC) |
| No. of Outputs | 10 (Relay) |
| On-State Voltage Range | 79 to 132V AC |
| Off-State Voltage Range | 0 to 20V AC |
| On-State Current | 5 mA @ 79VAC, 12 mA @ 120VAC, 16 mA @ 132VAC |
| Off-State Leakage Current | 2.5 mA max |
| Max Inrush Current (120V) | 250 mA |
| Operating Frequency | 47 to 63 Hz |
| Backplane Output | 400 mA @ 5VDC, 350 mA @ 24VDC |
| Communication Port | RS-232 Programmer/HMI (DH Full-Duplex) |
| Isolation Groups | 5 (input/backplane, output/backplane, input/input, output/output, power/backplane) |
| Mounting Dimensions | 3.5 x 4.33 x 3.43 in |
| Weight | Approx. 0.9 kg (2.0 lbs) |
| UPC | 10781180463836 |
| UNSPSC | 32151705 |
Installation Notes
Mount horizontally on DIN rail in a clean, dry environment. Connect 120-240VAC supply at 47-63 Hz. Use RS-232 Programmer/HMI port for local programming or HMI connection. The port supports DH Full-Duplex and responds to received messages only. Maintain proper isolation between input, output, and power groups. Ensure adequate ventilation for heat dissipation.
Engineering Advantages
All-in-one controller with integrated power supply and I/O reduces panel space. 14 AC inputs allow direct field device connection without interposing relays. 10 relay outputs handle both AC and DC loads. Five isolation groups protect against ground loops and noise. Dedicated RS-232 port enables HMI or network connection without additional modules.
FAQs
Q1: How many inputs and outputs does this controller have?
A1: 14 digital inputs (120VAC) and 10 relay outputs.
Q2: What communication port is available?
A2: One RS-232 Programmer/HMI port supporting DH Full-Duplex communication.
Q3: What is the input power requirement?
A3: 120-240VAC at 47-63 Hz operating frequency.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Can You Migrate ABB PLCs Without Stopping Production?
Aging ABB PLC platforms create rising reliability and spare-part risks for process plants. This article explains wher...
-
How Does Honeywell DCS Modernization Cut Refinery Downtime?
Honeywell DCS modernization helps refineries replace aging control hardware without full shutdowns. It tightens proce...
-
Why Do Hybrid DCS-PLC Systems Cause False Trips?
This article explains how to align Emerson DCS anti-surge control with ABB PLC compressor protection in hybrid ind...
-
How Can Brownfield Upgrades Modernize GE Fanuc DCS Visualization?
Aging GE Fanuc DCS visualization stacks create spare part delays, alarm chaos and unplanned downtime. This article ex...
-
Why Separate Safety PLC from GE Fanuc DCS?
Legacy GE Fanuc DCS platforms often merge process control with emergency trip logic, creating hidden risks durin...
-
How to Calibrate ABB PLC Signals for Emerson DCS Loops?
This article explains how to calibrate ABB PLC analog signals feeding Emerson DCS continuous process loops in hybrid ...
