Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1746-OB32E
Allen-Bradley 1746-OB32E 32-Channel Output Module 190mA
Manufacturer: Allen-Bradley
Product No.: 1746-OB32E
Product Type: Digital I/O Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1746-OB32E SLC 500 Digital DC Output Module
The Allen-Bradley 1746-OB32E is an SLC 500 digital DC output module featuring 32 electronically protected output channels. Operating from 10-30 V DC (nominal 24 V DC), each output delivers 0.5 A (0.25 A when all 32 outputs active). With 190 mA backplane current at 5 V DC and electronic short circuit/overload protection, this module provides reliable high-current output control. Weighing approximately 0.45 kg (1.0 lbs), it operates from -13°F to 140°F.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1746-OB32E |
| Series | SLC 500 |
| Module Type | Digital DC Output Module |
| Outputs | 32 (Two groups of 16) |
| Voltage Range | 10-30 V DC (Nominal 24 V DC) |
| Current per Output | 0.5 A (0.25 A all 32 active) |
| Current per Module | 8 A maximum |
| Points per Common | 16 |
| Backplane Current | 190 mA @ 5 V DC |
| Signal Delay (ON) | 0.1 ms |
| Signal Delay (OFF) | 1.0 ms |
| Step Response (In/Out) | 60 ms / 2.5 ms |
| Electronic Protection | Short Circuit & Overload (Auto-reset) |
| Operating Temperature | -13°F to 140°F (-25°C to 60°C) |
| Storage Temperature | -40°F to 185°F (-40°C to 85°C) |
| Humidity | 5-95% non-condensing |
| Vibration (Operating) | 2.5G @ 57-2000 Hz |
| Shock (Operating) | 30G |
| Weight | Approx. 0.45 kg (1.0 lbs) |
Model Number Breakdown
- 1746 – SLC 500 I/O Series
- O – Output Module
- B – DC Voltage (24 VDC)
- 32 – 32 Output Channels
- E – Electronically Protected
Installation & Field Application Guide
- Install in any available slot of the SLC 500 chassis. Ensure the power supply supports the 190 mA backplane draw.
- Wire field devices to the 32 output terminals. Use 14 AWG (2 mm²) cables with self-lifting lift plate terminals.
- Route input power to the module using a separate path from I/O device cables to reduce noise.
- External fusing is recommended despite electronic protection. The module auto-resets after overload; consider this for safe operation.
Why Choose the 1746-OB32E
- 32 outputs in a single SLC 500 module for high-density DC output control.
- Electronic short circuit and overload protection with auto-reset after fault clearance.
- 0.1 ms ON delay and 1.0 ms OFF delay for fast response applications.
- Individual fault detection per channel ensures unaffected outputs continue operation.
Field Engineer FAQs
Q1: What is the difference between 1746-OB32 and 1746-OB32E?
A1: The 1746-OB32E includes integral electronic protection against short circuits and overloads, while the standard OB32 does not.
Q2: What happens when an output overload is detected?
A2: The affected channel limits current output within milliseconds. The module auto-resets when the overload is cleared and resumes previous command state.
Q3: Does the electronic protection replace external fusing?
A3: No. The electronic protection is not equivalent to an external fuse. External protection devices are still recommended.
Inquiries: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can Unified DCS Architecture Cut Plant Downtime by 35%?
This article examines full-plant automation architecture through measurable outcomes from ABB DCS real-world deployme...
-
How Intelligent Scheduling Cuts Downtime & Boosts OEE 12%?
This article examines how intelligent production scheduling transforms industrial automation by replacing static spre...
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...