Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1746-OA16
Allen-Bradley 1746-OA16 120/240VAC 16 Point Output Module
Manufacturer: Allen-Bradley
Product No.: 1746-OA16
Product Type: Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 380g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Allen-Bradley 1746-OA16 is a 16-point discrete AC output module belonging to the SLC 500 modular I/O hardware system by Rockwell Automation. Designed for control of AC-powered actuators, solenoids, motor starters, and indicator lights, this module operates across a nominal 120/240 V AC supply voltage with a broad continuous operating range of 85 to 265 V AC (47–63 Hz).
Organized into two (2) individually isolated channels of eight (8) outputs each, the 1746-OA16 features optical coupling and integrated filter circuitry for signal noise suppression. Weighing approximately 0.38 kg (0.84 lbs), it installs into any single slot of an SLC 500 local or remote chassis, drawing 0.370 A (370 mA) from the 5.1 V DC backplane supply while providing convenient maintenance via removable terminal blocks (RTBs).
Core Technical Advantages
- Dual Grouped Channel Architecture: Configured with 16 AC output points split into two isolated groups of 8 channels, allowing distinct phase or voltage source control across banks.
- High Inrush Surge Handling: Supports surge currents up to 10.0 A per point for 25 ms, enabling safe switching of inductive loads without damaging output triacs.
- Removable Terminal Block (RTB) Design: Simplifies module replacement and field servicing without requiring the rewiring of individual field connections.
- Optical Noise Isolation & Status LEDs: Features full optical isolation between backplane logic and field side circuits, accompanied by front-panel status LEDs for rapid visual diagnostics.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation |
| Catalog Part Number | 1746-OA16 |
| Product Series | SLC 500 Modular I/O Series |
| Module Type | Digital / Discrete AC Output Module |
| Number of Outputs | 16 AC outputs (2 groups of 8 channels) |
| Nominal Output Voltage | 120 / 240 V AC (47 to 63 Hz) |
| Operating Voltage Range | 85 to 265 V AC |
| Continuous Current per Point | 0.50 A @ 30°C (86°F) | 0.25 A @ 60°C (140°F) |
| Continuous Current per Module | 8.0 A max @ 30°C (86°F) | 4.0 A max @ 60°C (140°F) |
| Minimum Load Current | 10 mA per channel |
| Surge Current per Point | 10.0 A maximum for 25 ms |
| On-State Voltage Drop | 1.50 V AC @ 0.50 A load current |
| Off-State Leakage Current | 2 mA maximum |
| Signal Delay Times | OFF-to-ON: 1 ms | ON-to-OFF: 11.0 ms |
| Backplane Current Consumption | 0.370 A (370 mA) @ 5.1 V DC |
| Slot Width & Wiring Wiring | Single slot / Removable Terminal Block (RTB) |
| Operating Temperature / Humidity | 0°C to 60°C (32°F to 140°F) | 5% to 95% Non-condensing |
| Estimated Shipping Weight | Approx. 0.38 kg (0.84 lbs) |
Installation & Handling Guidelines
- Chassis Power Off: Always remove system power from the SLC 500 chassis before inserting or removing the 1746-OA16 module to prevent backplane damage.
- Terminal Block Removal: Utilize the release tabs on the Removable Terminal Block (RTB) to disconnect field wiring as a single unit when replacing hardware.
- Thermal Derating Verification: Ensure load currents stay under 0.25 A per point if cabinet operating temperatures exceed 30°C (86°F) up to the 60°C (140°F) threshold.
Technical FAQs
Q1: What is the continuous current rating per point for the Allen-Bradley 1746-OA16 module?
A1: It supports 0.50 A per point at 30°C, derating to 0.25 A per point at 60°C.
Q2: How much backplane current does the 1746-OA16 module draw?
A2: The module consumes 370 mA (0.370 A) at 5.1 V DC from the SLC chassis power supply.
Q3: Does the 1746-OA16 output module require wiring removal during replacement?
A3: No, it features a removable terminal block (RTB) that allows module swapping without disconnecting individual wires.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...