Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1746-IV32
Allen-Bradley 1746-IV32 | 24V Sourcing Input 4 Groups
Manufacturer: Allen-Bradley
Product No.: 1746-IV32
Product Type: Discrete Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1746-IV32 SLC 500 Discrete Input Module
Product Overview
The Allen-Bradley 1746-IV32 is a 24 VDC sourcing input module for the SLC 500 platform. It features thirty-two (32) input channels arranged in four (4) groups of eight (8) channels each. Operating voltage ranges from 15 to 30 VDC at 50 °C with a backplane current draw of 106 mA at 5 VDC. Weight is 0.35 kg.
Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1746-IV32 |
| Series | SLC 500 |
| Module Type | 24 VDC Discrete Input Module |
| Inputs | 32 (4 groups of 8) |
| Input Voltage Range (50 °C) | 15-30 VDC |
| Input Voltage Range (60 °C) | 15-26.4 VDC |
| Nominal Input Current | 5.1 mA @ 24 VDC |
| On-State Voltage Min | 15.0 VDC |
| Off-State Voltage Max | 5.0 VDC |
| Off-State Current Max | 1.5 mA |
| Signal Delay ON | 3 ms max |
| Signal Delay OFF | 8 ms max |
| Backplane Current (5V) | 106 mA |
| Backplane Current (24V) | 0 A |
| Isolation from Backplane | 1500 VAC for 1 min |
| Heat Dissipation per Point | 0.20 W |
| Total Heat Dissipation | 6.65 W |
| Fuse Rating (Series A-C) | 2.5 A per common (non-replaceable) |
| Operating Temperature | 0 to 60 °C |
| Storage Temperature | -40 to 85 °C |
| Relative Humidity | 5-95% (non-condensing) |
| Operating Vibration | 2.5G at 57-200 Hz |
| Operating Shock | 30G |
| Weight | 0.35 kg |
Key Features
- 32 digital input channels in 4 isolated groups of 8
- 15-30 VDC input voltage range (15-26.4 VDC at 60 °C)
- 5.1 mA nominal input current at 24 VDC
- 3 ms ON delay, 8 ms OFF delay
- 1500 VAC isolation from backplane for 1 minute
- CE, CSA, and UL certified
- Class I Division 2 hazardous location approved
- NEMA ICS 2-230 noise immunity
- Series A-C include non-replaceable 2.5A fuses per common
- Install in any SLC 500 chassis slot
- Supports local, extended, and distributed I/O racks
Installation Notes
Install the module in any slot of the SLC 500 chassis. Series A, B, and C have non-replaceable 2.5A fuses per input common. Series D has no internal group fusing. Ensure input voltage does not exceed 30 VDC. For 60 °C operation, voltage range is limited to 15-26.4 VDC. Use in Class I Division 2 hazardous locations requires proper installation per certification guidelines.
FAQs
Q1: How many input channels does the 1746-IV32 have?
A1: 32 channels arranged in 4 groups of 8 channels each.
Q2: What is the input voltage range?
A2: 15-30 VDC at 50 °C, derated to 15-26.4 VDC at 60 °C.
Q3: What is the signal delay for this module?
A3: 3 ms ON delay maximum, 8 ms OFF delay maximum.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...