Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1746-ITB16
Allen-Bradley 1746-ITB16 24VDC 16-Channel Fast Module
Manufacturer: Allen-Bradley
Product No.: 1746-ITB16
Product Type: Discrete I/O Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 230g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1746-ITB16 Technical Overview
The Allen-Bradley 1746-ITB16 is a fast-response discrete digital input module in the SLC 500 series manufactured by Rockwell Automation. Designed for high-speed switching and time-critical applications, this lightweight module weighs approximately 0.23 kg (0.51 lbs) and features 16 sinking input channels operating at a nominal voltage of 24 VDC (10–30 VDC range). It integrates optical coupling and filter circuitry for noise reduction, removable terminal blocks for easy maintenance, and LED status indicators for real-time channel diagnostics across operating temperatures from 0 °C to 60 °C (32 °F to 140 °F).
Part Number Breakdown
- 1746: Allen-Bradley SLC 500 Hardware Chassis & I/O Architecture Series
- -ITB: Fast-Response DC Digital Sinking Input Hardware Type
- 16: 16-Channel Input Point Density
Technical Specifications Table
| Parameter | Specification |
|---|---|
| Manufacturer / Brand | Rockwell Automation / Allen-Bradley |
| Full Part Number | 1746-ITB16 |
| Product Line & Module Type | SLC 500 Series / Fast Response Discrete Sinking Input |
| Number of Inputs & Wiring | 16 Channels / Sink Wiring Configuration (1 Group of 16) |
| Nominal Voltage & Voltage Range | 24 VDC Nominal / 10 to 30 VDC Operating Range |
| Nominal Input & Backplane Current | 8 mA @ 24 VDC / 85 mA (0.085 A) @ 5 VDC Backplane |
| Off-State Voltage & Current | 5 VDC Maximum Off-State / 1.5 mA Maximum Off-State Current |
| Signal Delay (Resistive Load) | ON = 0.3 ms (max 0.43 ms) / OFF = 0.5 ms |
| Physical Module Weight | Approx. 0.23 kg (0.51 lbs) Net Weight |
| Power Dissipation | 3.6 W Maximum Power Dissipation |
| Operating Temp & Humidity | 0 °C to +60 °C (32 °F to 140 °F) / 5% to 95% Non-Condensing |
Key Features & Hardware Configurations
Features 16 fast-response 24VDC sinking inputs, 85 mA backplane current, 0.23 kg weight, sub-millisecond signal delay, and optical noise isolation.
Frequently Asked Questions (FAQs)
Q1: What are the primary specifications of the Allen-Bradley 1746-ITB16?
A1: 16 sinking DC inputs, 24 VDC nominal voltage, 0.23 kg weight, 85 mA backplane current, and fast signal delays.
Q2: Can the 1746-ITB16 be removed under power (RIUP)?
A2: No, this module does not support RIUP. Always disconnect power from the SLC 500 chassis before installation or removal.
Q3: How does this module perform with high-speed pulse inputs?
A3: When paired with SLC 5/03 or 5/04 processors using Discrete Input Interrupt (DII) instructions, it can read pulse frequencies up to 1 kHz (or 2 kHz with Gray code encoders).
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...
