Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1746-IB8
Allen-Bradley 1746-IB8 SLC 500 Digital Input Module 8 Channel 24V
Manufacturer: Allen-Bradley
Product No.: 1746-IB8
Product Type: Digital Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1746-IB8 SLC 500 Digital DC Input Module
The Allen-Bradley 1746-IB8 is an SLC 500 digital DC input module featuring 8 sinking input channels rated at 24 V DC. Operating from 10-30 V DC, this module provides reliable field signal acquisition for industrial control systems. Approved for Class 1 Division 2 hazardous locations, it draws 50 mA backplane current at 5 V DC and dissipates 1.3 W. Weighing approximately 0.3 kg (0.66 lbs), it operates from 0°C to 60°C.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1746-IB8 |
| Series | SLC 500 |
| Module Type | Digital DC Input Module |
| Inputs | 8 (Sinking) |
| Voltage Range | 10-30 V DC |
| Nominal Voltage | 24 V DC |
| Nominal Input Current | 8 mA @ 24 V DC |
| Off-State Current | 1 mA max |
| Off-State Voltage | 5.0 V DC max |
| Signal Delay (ON/OFF) | 8 ms |
| Backplane Current | 50 mA @ 5 V DC |
| Power Dissipation | 1.3 W (4.4 BTU/hr) |
| Dielectric Withstand | 1500 V AC |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Humidity | 5-95% non-condensing |
| Vibration | 2.5G @ 57-500 Hz |
| Shock | 30G |
| Approvals | UL, CE, Class 1 Div 2 |
| UPC | 10662073521256 |
Model Number Breakdown
- 1746 – SLC 500 I/O Series
- I – Input Module
- B – DC Voltage, Sinking Input
- 8 – 8 Input Channels
Installation & Field Application Guide
- Install in any available slot of the SLC 500 chassis. Ensure the power supply supports the 50 mA backplane draw.
- Wire field devices to the 8 input terminals using appropriate gauge wire. Inputs are sinking type.
- Verify field voltage is between 10-30 V DC. Nominal input current is 8 mA at 24 V DC.
- For Class 1 Division 2 installations, follow hazardous area wiring practices and use approved barriers.
Why Choose the 1746-IB8
- 8 sinking inputs provide reliable DC signal acquisition for SLC 500 systems.
- Class 1 Division 2 approval for hazardous area installations.
- Low backplane current (50 mA) minimizes power supply loading.
- Proven reliability with UL, CE, and NEMA Noise Immunity certification.
Field Engineer FAQs
Q1: What is the difference between sinking and sourcing inputs on the 1746-IB8?
A1: The 1746-IB8 provides sinking inputs, meaning the input connects to the common (ground) to turn on. The input circuit sources current to the field device.
Q2: Can the 1746-IB8 be used with 24 V AC signals?
A2: No, this module is designed for DC input signals only. Use the 1746-IA8 for AC input applications.
Q3: What is the maximum cable length for field wiring to the 1746-IB8?
A3: Maximum recommended cable length is 305 meters (1000 feet) for reliable signal detection.
Inquiries: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...