Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:V18345-2010521501
ABB V18345 | Double Acting Fail Freeze Positioner
Manufacturer: ABB
Product No.: V18345-2010521501
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
ABB V18345-2010521501 Electro-Pneumatic Positioner
The V18345-2010521501 (also cataloged as the V18345 TZIDC Electro-Pneumatic Positioner) is a double-acting fail-freeze positioner in a varnished aluminium case rated IP 65 / NEMA 4X with a mechanical position indicator. It accepts a 4-20 mA two-wire input and includes a plug-in 4-20 mA analog feedback module plus 24 V DC/AC microswitch feedback. Unit weight is 1.7 kg.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | V18345-2010521501 |
| Brand | ABB |
| Product Type | TZIDC Electro-Pneumatic Positioner |
| Weight | 1.7 kg |
| Input Signal | 4-20 mA, two-wire, LKS adapter connector plug |
| Impedance at 20 mA | 435 ohms |
| Output Function | Double acting, fail freeze |
| Output Range | 0 to 6 bar (0 to 90 psi) |
| Air Consumption | < 0.03 kg/h / 0.015 scfm |
| Characteristic Deviation | <= 0.5 % |
| Resolution | > 4000 steps |
| Sample Rate | 20 msec |
| Operating Temp | -40 deg C to +85 deg C |
| Housing | Aluminium, IP 65 / NEMA 4X, RAL 9005 matte black |
| Digital Feedback | 24 V DC/AC microswitches, change-over contacts |
| Communication | HART Protocol 5.1, LKS local connector |
Frequently Asked Questions
Q: What is the fail-safe action and output range of the V18345-2010521501?
A: Double acting, fail freeze; output range 0 to 6 bar (0 to 90 psi).
Q: What is the HART protocol version and operating temperature range?
A: HART Protocol 5.1; -40 deg C to +85 deg C for operation, storage, and transport.
Q: What digital position feedback is included in this configuration?
A: 24 V DC/AC microswitches with change-over contacts.
Ƙarin ƙayyadaddun bayanai
- Azurfa
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
