Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:SS823
ABB SS823 3BSE038226R1 Voting Unit 20A Redundant
Manufacturer: ABB
Product No.: SS823
Product Type: Power Voting Unit
Product Origin: USA
Payment:T/T, Western Union
Weight: 870g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
ABB SS823 3BSE038226R1 Voting Unit
The ABB SS823 3BSE038226R1 Voting Unit is designed for redundant power supply configurations. It separates redundant power supplies, supervises voltage, and generates supervision signals for power consumers. Certified for SIL3 according to IEC 61508, it ensures high integrity power distribution for AC 800M and S880 I/O systems.
Product Identification
- Manufacturer: ABB
- Article Number: 3BSE038226R1
- Type: Voter and Over Voltage Protection
- High Integrity: Yes
Electrical Specifications
| Parameter | Value |
|---|---|
| Rated Output Current | 20 A |
| Rated Input Power | 500 W |
| Nominal Input Voltage | 24V DC |
| Input Frequency | 60 V DC |
| Load Sharing | Yes |
| Supervision Relay | Yes |
| Max Output Current (Overload) | 35 A |
| Output Overvoltage Protection | < 30 V |
| Heat Dissipation (20A) | 24 W |
| Heat Dissipation (5A) | 6 W |
| Output Voltage Regulation | 1.2 V lower than input |
Physical Specifications
| Parameter | Value |
|---|---|
| Width | 116 mm (4.6 in) |
| Depth (including connector) | 145 mm (5.8 in) |
| Height | 132 mm (5.3 in) |
| Weight | 870 g (1.9 lb) |
| Mounting Spacing (W) | 15 mm (0.59 in) |
| Mounting Spacing (H) | 30 mm (1.2 in) |
| Protection Rating | IP20 |
| Max Ambient Temperature | 55°C |
Features and Benefits
- DIN-rail mounting for easy installation.
- Double overvoltage protection on both inputs.
- Detects short and open circuits in voting element.
- Green LEDs provide visual indication of correct output voltage.
- Voltage-free contacts for supervision signaling.
- Class I Equipment with protective earth connection.
- Over-voltage Category III for primary mains connection.
- Protective separation of secondary from primary circuit.
- Accepted for SELV and PELV applications.
- Output protected against overcurrent (current limit) and overvoltage (OVP).
- Certified for SIL3 according to IEC 61508.
- G3 compliant for corrosive atmospheres.
Environment and Certification
| Certification | Status |
|---|---|
| CE Mark | Yes |
| Electrical Safety | IEC 61131-2, EN 50178 |
| ATEX Zone 2 | Yes |
| Marine Certification | ABS, BV, DNV-GL, LR |
| Corrosive Atmosphere | ISA-S71.04 G3 |
| Pollution Degree | Degree 2 (IEC 60664-1) |
| EMC | EN 61000-6-4, EN 61000-6-2 |
| RoHS Compliance | 2011/65/EU |
Installation
- Mount on DIN rail with specified spacing (15mm W, 30mm H).
- Connect to protective earth (PE) for Class I equipment.
- Connect two power supply outputs to voting unit inputs.
- Connect supervision signals to power consumer.
- Ensure ambient temperature does not exceed 55°C.
- Verify SELV/PELV compliance for connected loads.
Technical FAQs
Q1: What is the rated output current of the SS823?
A1: 20 A continuous, with 35 A overload capability.
Q2: What certifications does the SS823 hold?
A2: SIL3 (IEC 61508), ATEX Zone 2, and marine certifications (ABS, BV, DNV-GL, LR).
Q3: How does the voting unit indicate correct operation?
A3: Green LEDs on the front panel provide visual indication, and voltage-free contacts close for supervision signaling.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...