Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:V18345-1010121001
ABB Electro-Pneumatic Positioner TZIDC IP65 V18345-1010121001
Manufacturer: ABB
Product No.: V18345-1010121001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
ABB V18345-1010121001 TZIDC Electro-Pneumatic Positioner
Product Overview
ABB V18345-1010121001 is an intelligent, configurable electro-pneumatic positioner from the TZIDC series with indicator and operator panel. Features varnished aluminum case IP65 (NEMA 4X) for mounting to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Accepts 4-20mA two-wire input with LKS adapter connector plug. Single acting fail safe action. Includes plug-in analog position feedback module 4-20mA. Weight 1.7 kg.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| Base | V18345 | TZIDC intelligent, configurable with indicator and operator panel |
| Case/Mounting | 1 | Varnished aluminum IP65, DIN/IEC 534/NAMUR or VDI/VDE 3845 |
| Input/Communication | 1 | 4-20mA two-wire with LKS adapter connector |
| Explosion Protection | 0 | Without |
| Output/Safe Position | 1 | Single acting, fail safe |
| Connections | 2 | Cable 1/2-14 NPT, Air 1/4-18 NPT |
| Option Modules | 1 | Plug-in analog position feedback 4-20mA |
| Mech Feedback | 0 | Without |
| Design | 1 | Standard |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | ABB |
| Model | V18345-1010121001 |
| Type | TZIDC Electro-Pneumatic Positioner |
| Action | Single Acting, Fail Safe |
| Output Signal | 4 to 20 mA two-wire |
| Digital Input | 0 to 5V DC (logic 0), 11 to 30V DC (logic 1) |
| Digital Output | 5 to 11V DC per DIN 19234/NAMUR |
| Supply Pressure | 1.4 to 6 bar (20 to 90 psi) |
| Air Consumption | < 0.03 kg/h (0.015 scfm) |
| Housing Material | Aluminum, epoxy resin varnish |
| Protection Class | IP65, NEMA 4X |
| Electrical Connection | 2 threads 1/2-14 NPT or M20x1.5 |
| Pneumatic Connection | G 1/4 or 1/4-18 NPT |
| Screw Terminals | Max 1.0 mm² (options), max 2.5 mm² (analog) |
| Operating Temperature | 40°C to +85°C |
| Humidity Operational | 95% annual average, condensation permissible |
| Humidity Storage | 75% annual average, non condensing |
| Weight | 1.7 kg |
Installation
Mount on linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Ready for integral mounting. Connect 4-20mA two-wire input with LKS adapter. Wire electrical connection at 1/2-14 NPT or M20x1.5. Connect air supply at G 1/4 or 1/4-18 NPT with 1.4 to 6 bar pressure. Do not expose terminals to strain. Verify IP65 seal after installation.
Features
Intelligent configurable positioner with indicator and operator panel. Single acting fail safe action for power failure safety. 4-20mA two-wire input with LKS adapter connector. Plug-in analog position feedback module 4-20mA. Air consumption less than 0.03 kg/h independent of supply pressure. Aluminum case with epoxy resin varnish. IP65 NEMA 4X protection. Operating temperature 40°C to +85°C. Humidity tolerance 95% with condensation permissible.
FAQ
Q1: What is the action type and fail position?
A1: Single acting with fail safe action. In case of electrical power failure, the valve moves to its safe position. 4-20mA two-wire input with LKS adapter.
Q2: What are the pneumatic and electrical connection sizes?
A2: Electrical 1/2-14 NPT or M20x1.5. Pneumatic G 1/4 or 1/4-18 NPT. Supply pressure 1.4 to 6 bar (20 to 90 psi).
Q3: What is the air consumption and operating temperature?
A3: Air consumption less than 0.03 kg/h independent of supply pressure. Operating temperature 40°C to +85°C. IP65 NEMA 4X protection.
Ƙarin ƙayyadaddun bayanai
- Azurfa
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...