Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1SAP250700R0001
ABB DA501 1SAP250700R0001 | S500 Digital/Analog I/O Module
Manufacturer: ABB
Product No.: 1SAP250700R0001
Product Type: Digital I/O Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 121g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The ABB DA501 (1SAP250700R0001) is a digital/analog I/O module from the S500 series. It combines 16 digital inputs, 4 analog inputs (U, I, RTD), 2 analog outputs (U, I), and 8 configurable digital inputs/outputs in a single compact unit. This module delivers flexible I/O expansion for industrial automation systems.
Core Functionality
The DA501 integrates digital and analog signal processing in one module. The 16 digital inputs accept 24V DC signals at 5mA. Four analog inputs support voltage, current, and RTD sensors with 13-bit resolution. Two analog outputs provide voltage or current signals, also 13-bit. Eight additional channels are configurable as either digital inputs or 0.5A transistor outputs, maximizing application flexibility.
Technical Specifications
| Parameter | Value |
| Product ID | 1SAP250700R0001 |
| Type Designation | DA501 |
| Digital Inputs | 16 (24V DC, 5mA) |
| Analog Inputs | 4 (U, I, RTD) |
| Analog Outputs | 2 (U, I) |
| Configurable DI/DO | 8 (24V DC, 0.5A) |
| Resolution | 13-bit (AI and AO) |
| Max Input Voltage | 30V |
| Delay Time | 0.1 to 32 ms |
| Output Type | Transistor |
| Supply Voltage | 24V DC (20.4-28.8V) |
| Protection | IP20 |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -40°C to +70°C |
| Dimensions (W x H x D) | 67.5 x 76 x 62 mm |
| Weight | 0.121 kg |
Installation Guide
Mount the DA501 on DIN rail within the S500 I/O rack. Connect 24V DC supply (20.4-28.8V). Wire digital inputs, analog inputs (voltage, current, or RTD), analog outputs, and configurable DI/DO channels per the terminal assignment. For RTD inputs, use 3-wire connections for optimal accuracy. Observe IP20 protection requirements by installing in a suitable enclosure.
Engineering Advantages
This module combines digital and analog I/O in one compact unit, saving panel space. Eight configurable channels adapt to changing application needs. 13-bit resolution on both analog inputs and outputs ensures precise signal handling. Wide delay time range (0.1-32ms) accommodates diverse filtering requirements. At just 0.121 kg, it minimizes DIN rail loading.
Technical FAQs
Q1: What I/O does the DA501 provide?
A1: 16 digital inputs (24V DC, 5mA), 4 analog inputs (U/I/RTD), 2 analog outputs (U/I), and 8 configurable DI/DO (24V DC, 0.5A).
Q2: Analog resolution and signals?
A2: 13-bit resolution for analog inputs and outputs. Inputs support voltage, current, and RTD signals. Outputs support voltage and current.
Q3: Power and protection ratings?
A3: 24V DC supply (20.4-28.8V range). IP20 housing protection. Operating temperature 0 to +60°C.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
-
What Makes Bently Nevada System 1 Essential for Predictive Maintenance?
Bently Nevada System 1 is a dedicated vibration analytics platform that pairs with 3500 TSI racks to deliver hig...
-
Is ABB MOD300 DCS Migration Still Worth the Investment?
ABB Advant MOD300 systems still run in many refineries and power plants, yet aging capacitors, scarce spares and hidd...
