Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:490176087
ABB 490176087 S200-IR8 Temperature Module 8 Channel 4-20mA
Manufacturer: ABB
Product No.: 490176087
Product Type: Temperature Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 100g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
ABB 490176087 S200-IR8 Temperature Module
Product Overview
ABB 490176087 (S200-IR8) is an 8 channel temperature input module from ABB. It accepts temperature signals from -40°C to +120°C and converts to 4-20mA analog output. DIN rail mounted with IP20 protection. Operates on 24V DC with ±0.5% accuracy. CE and UL compliant.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | ABB |
| Model | 490176087 / S200-IR8 |
| Type | Temperature Input Module |
| Inputs | 8 channels |
| Temperature Range | 40°C to +120°C |
| Output Type | Analog 4-20mA |
| Accuracy | ±0.5% of full scale |
| Input Voltage | 24V DC |
| Operating Temperature | 20°C to +60°C |
| Protection Class | IP20 |
| Mounting | DIN Rail |
| Dimensions W x H x D | 102 x 51 x 51 mm (4.0 x 2.0 x 2.0 in) |
| Weight | 0.1 kg |
| Standards | CE, UL |
Installation
Clip ABB module onto DIN rail. Connect 24V DC power supply. Wire temperature sensors to 8 input channels. Connect 4-20mA output to PLC or controller. Ensure proper grounding. Operating temperature 20°C to +60°C.
Features
ABB 8 temperature input channels. 4-20mA analog output. ±0.5% accuracy. DIN rail mounting. IP20 protection. CE and UL compliant. Compact design.
FAQ
Q1: What is the temperature measurement range of the ABB 490176087?
A1: 40°C to +120°C. Suitable for industrial temperature monitoring applications.
Q2: What is the output signal of this ABB module?
A2: 4-20mA analog output. Connect directly to PLC analog input modules.
Q3: What is the accuracy of the ABB S200-IR8?
A3: ±0.5% of full scale. Calibrate per application requirements for optimal performance.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Do You Tune a 3500/92 Gateway for Stable Modbus TCP Polling?
This article explains why Bently Nevada 3500/92 Modbus TCP gateways fail in industrial control systems and how automa...
-
How Can You Prevent GE PLC Backup Failures?
This article explains why GE PLC backup failures occur in RX3i and VersaMax environments. It presents measured root c...
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
