Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:CI920AN
ABB 3BDH000692R1 CI920AN Advant 800xA Communication Interface
Manufacturer: ABB
Product No.: CI920AN
Product Type: I/O Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 130g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Core Technical Advantages
Seamless HART Field Device Pass-Through
The CI920AN natively supports HART protocol bridging over the PROFIBUS DP network configuration. This allows maintenance engineering teams to perform asset management operations, calibrate remote transmitters, change process parameters, and view advanced health metrics directly from the central control room without running dedicated secondary instrumentation wires.
Advanced System and Network Redundancy
To maximize uptime in critical continuous-process environments, the CI920AN supports full master/slave line redundancy. If a primary master module failure or a network cable break is detected, the redundant standby configuration takes over the communication bus instantaneously, ensuring zero data drops or unexpected automated plant shutdowns.
Rugged S900 Modular Architecture
Part of the rugged S900 system platform, the CI920AN features an extremely small physical footprint (20mm thickness), optimizing DIN rail real estate inside control marshaling panels. Its energy-efficient internal circuitry generates minimal thermal load, contributing to its broad ambient operating spectrum and long-term lifespan.
Technical Specifications
| Parameter Code | Specification Details |
|---|---|
| Brand / Manufacturer | ABB Automation |
| Catalog Part Number | 3BDH000692R1 |
| Model Identification | CI920AN (Non-IS Version) |
| Signal / Module Type | PROFIBUS DP Remote I/O Communication Interface |
| HART Protocol Compatibility | Yes (Supports cyclic and acyclic HART parameter routing) |
| Redundancy Support | Yes (Supports dual redundant network line topologies) |
| Mechanical Classification | S900 Sub-rack Mountable Module |
| Dimensions (W x D x H) | 20 x 104 x 104 mm (0.79 x 4.09 x 4.09 inches) |
| Operating Temperature Range | -20°C to 60°C (-4°F to 140°F) |
| Environmental Compliance | CE Marked, RoHS Directive 2011/65/EU, WEEE Small Equipment |
Installation and Maintenance
S900 Slot Mounting and Hot-Swap Guidelines
The CI920AN is engineered to snap directly into the designated communication slots on an S900 terminal unit or backplane chassis. To install, align the rear connector pin layout with the sub-rack guide tracking channels and press firmly until the locking tabs snap into place. The module supports live-insertion/hot-swapping configurations, allowing maintenance teams to change components without interrupting power to the remaining active I/O rack segments.
Redundant Bus Line Termination and Configuration
When implementing redundant topologies, install dual CI920AN modules into the corresponding primary and secondary sub-rack slots. Ensure the interconnecting PROFIBUS DP cables are terminated using high-quality network plugs with integrated terminating resistors active on both ends of the segment to avoid signal reflections and data communication corruption.
Climatic Control and Environmental Preservation
The module is certified to perform across a broad temperature scale (-20°C to 60°C) and withstand non-condensing relative humidity levels up to 93% (±3% at 40°C). For outdoor marshaling applications or environments high in ambient particulate count, house the S900 system sub-rack assembly within a sealed, climate-controlled cabinet matching IP65 or NEMA 4 standards.
Engineering Advantages
Direct System 800xA Optimization
By routing field information through standard PROFIBUS DP layers, the CI920AN offers smooth integration with ABB’s core asset optimization software utilities. This integration maps process inputs, diagnostic registers, and status alerts directly into the operator workstation environment without requiring complex ladder logic rewriting.
Reduced Engineering and Wiring Overhead
Combining many analog and digital I/O clusters onto a single serial communication line reduces the total volume of field cables running back to the main control station. This distributed I/O framework simplifies project engineering, lowers installation costs, and reduces the time required for system commissioning.
Comprehensive Compliance Standards
Complying with strict European CE mandates, RoHS Directive 2011/65/EU, and falling into the WEEE Small Equipment category (external dimensions ≤ 50cm), this module meets environmental and electronic safety standards required for global infrastructure, power generation, and manufacturing applications.
Technical FAQs
Q1: Can the CI920AN 3BDH000692R1 be installed directly in ATEX Zone 1 hazardous explosive zones?
A1: No. While the S900 family contains modules specifically engineered for intrinsically safe field areas, the CI920AN (Model Code ending with 'N') is classified as a non-intrinsically safe interface module. It should be mounted inside a safe area or within a flame-proof / purged enclosure when used in hazardous industrial settings.
Q2: How does the CI920AN handle a sudden failure of the primary PROFIBUS line?
A2: When deployed in a redundant configuration with a secondary backup module, both units monitor network status in real time. If the active communication channel fails or experiences a broken cable, the internal firmware switches to the redundant link within milliseconds, ensuring uninterrupted control loop data tracking.
Q3: Does this module require specialized software toolsets for initial node address assignment?
A3: Initial node station addresses can typically be configured using standard hardware configuration switches located on the module/backplane housing, or established via PROFIBUS network master configuration software utilities during system integration.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can DeltaV Redundant DCS Eliminate Oil & Gas Shutdowns?
This article examines Emerson DeltaV DCS redundant architecture for oil and gas, presenting outage cost data, 1:1 red...
-
Why Are Legacy PLCs the Biggest Risk in New Energy Smart Factories?
This technical article examines how Allen‑Bradley Safety PLC resolves the safety-efficiency paradox in lithium batter...
-
Can Bently Nevada + GE Fanuc PLC Prevent Mill Shutdowns?
This article examines Bently Nevada sensors integrated with GE Fanuc PLC for predictive maintenance in metallurgy. 20...
-
What Is the Data-Driven Strategy for Guaranteeing Genuine Control Spares?
Fragmented spare parts procurement causes 68% of unplanned plant shutdowns and inflates costs by 22% annually. This e...
-
Can GE Fanuc-Emerson Integration Cut OPEX 18%?
A regional refinery cut downtime 28% and energy use 18% via GE Fanuc PLC-Emerson DCS integration. Retained legacy har...
-
Why Do 78% of Digital Retrofits Fail Without Edge Data?
This technical article examines how Emerson's industrial edge gateway resolves multi-vendor OT interoperability chall...