Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:9905-204
9905-204 Woodward DSM Synchronizer Module
Manufacturer: Woodward
Product No.: 9905-204
Product Type: Digital Synchronizer Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 3200g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
9905-204 Woodward DSM Synchronizer Module
Product Overview
The 9905-204 Woodward DSM is a dedicated digital synchronizer for generator and turbine parallel operation. It delivers precise voltage matching (±1%) and phase-angle control, ensuring seamless bus coupling in 115/230V-AC systems. Built for extreme environments, this module operates reliably from -35 to 65 °C.
Core Advantages
Rugged 125V dc supply. Small sync window for rapid closure. Non-intrusive speed matching. Direct retrofit for 9900 series and legacy Woodward controls. LED status indicators for voltage, speed, and breaker commands.
Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | 9905-204 |
| AC Voltage | 115/230V-AC |
| DC Supply | 125 V dc |
| Voltage Matching | ±1% |
| Sync Window | Small (adjustable) |
| Operating Temp | -35 to 65 °C |
| Board Size | 33.0 x 17.8 cm |
| Module Depth | 8.25 x 4.27 cm |
Installation Quick Notes
Gap voltage: Set to 2.5 Vdc at speed input (terminals 5-6). Cable: Use shielded twisted pairs; min bend radius 50 mm. Grounding: Follow local ex-proof codes for hazardous areas.
Why Choose 9905-204
Engineered for high-vibration turbine decks. The small sync window reduces mechanical stress. ±1% voltage accuracy ensures stable load sharing. Fully compatible with 3300 series and older Woodward AVRs.
FAQs
Q1: How to set the gap voltage?
A1: Adjust trimmer until 2.5 Vdc is measured at terminals 5-6 with generator at rated speed.
Q2: Retrofit for 3300 series?
A2: Yes, it supports analog/digital outputs for 3300, 2301A, and most AVRs via jumpers.
Q3: What does small sync window do?
A3: Narrows phase-angle tolerance (e.g., ±2°) for reduced mechanical stress and longer turbine life.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Is Compact DCS Better Than PLC for Small Plants?
This article examines the ABB AC700F Freelance DCS as a compact control solution for small batch process plants ...
-
What Makes ControlEdge UCD Ideal for Water Treatment DCS?
Honeywell ControlEdge UCD DCS delivers DCS-grade reliability in a compact, PLC-like footprint suited to mid-size muni...
-
Why Is Redundant DCS Essential for 24/7 Process Automation?
ABB Freelance AC900F redundant DCS delivers hot standby CPU switching within 5 ms, hot-swappable S700 I/O, and verifi...
-
What Makes Honeywell C200 DCS Installation Standards So Critical?
This article examines Honeywell Experion PKS C200 DCS installation standards, key technical parameters, CPU and I/O f...
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...