8440-1956 Woodward easYgen 3000 Engine Generator Control Module

A kan haja (16 guda), a shirye don aikawa
  • Manufacturer: Woodward

  • Product No.: 8440-1956

  • Product Type: Operator Interface

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1850g

  • Shipping port: Xiamen

  • Warranty: 12 months

Dokar Mayar da Kaya na Kwanaki 30 · Garantin Watanni 12
  • Isarwa Cikin Gaggawa
  • Tallafi na awa 24 a rana, kwana 7 a mako
  • Tabbacin Inganci

Bayani

Product Overview

The 8440-1956 (model designation: easYgen-3400-1-P1) is an engine generator controller engineered by Woodward Inc. as part of the easYgen-3000 series for complex breaker applications. Housed in a durable metal frame, this controller features a 1 A CT input, Accuracy Class 0.5 precision, and a multi-lingual display supporting 15 languages including English, German, Spanish, French, and Chinese. It provides comprehensive generator voltage monitoring (delta or wye configurations) with configurable A through F alarm classes. Weighing approximately 1.85 kg (4 lbs), the unit manages setting power ranges from 0.5 to 99,999.9 kW/kvar in critical generator management systems.

Core Technical Advantages

  • Precision Power & Voltage Monitoring: Delivers Accuracy Class 0.5 measurement with configurable wye/delta voltage sensing to prevent earth faults.
  • Multi-Lingual User Interface: Built-in display support for 15 international languages simplifies field operation and diagnostics worldwide.
  • Flexible Alarm Management: Configurable alarm classes (A through F) allow precise threshold limit assignments and automated protective trip actions.

Technical Specifications

Parameter Specification Details
Brand & Manufacturer Woodward Inc.
Product Series Family easYgen-3000 Series
Part Number 8440-1956
Model Designation easYgen-3400-1-P1
Application Field Engine Generator Control (Complex Breaker Applications)
Current Transformer (CT) Input 1 A CT Input
Measurement Accuracy Class Class 0.5
Setting Power Range 0.5 to 99,999.9 kW / kvar
Relay Contact Material AgCdO (Silver Cadmium Oxide)
Alarm Configuration Classes Classes A / B / C / D / E / F
Display Language Support English, German, Spanish, French, Italian, Portuguese, Japanese, Chinese, Russian, Turkish, Polish, Slovakian, Finnish, Swedish
Enclosure Construction Metal Frame Enclosure
Ambient Operating Humidity 95%, non-condensing
Product Net Weight Approx. 1.85 kg (1,850 g / 4 lbs)

Industrial Applications

  • Genset Power Generation: Manages complex breaker operations and synchronization for diesel and gas engine generators.
  • Paralleling Control Systems: Coordinates load sharing and generator voltage/frequency matching across utility grids.
  • Emergency Standby Power: Controls automatic transfer switches and utility protection in critical infrastructure facilities.

Wiring & Installation

  • Panel Frame Inspection: Inspect metal housing for transit damage before mounting to prevent mechanical and frame grounding hazards.
  • Voltage Sensing Setup: Wire generator voltage sensing in wye (phase-neutral) configuration for isolated networks to ensure earth-fault protection.
  • CT & Contact Connections: Connect 1 A current transformer secondary loops and AgCdO relay contact outputs to specified control terminals.

Engineering Advantages

  • Compact P1 Form Factor: Optimized panel footprint compared to P2 series modules while providing core generator control functionality.
  • High-Durability Contacts: AgCdO contact materials deliver reliable switching endurance under continuous duty cycles.
  • Solid Metal Housing: Structural metal frame provides EMI shielding and physical rigidity in generator enclosure panels.

Technical FAQs

Q1: What CT input rating does the Woodward 8440-1956 controller require?
A1: The module is designed specifically for 1 A secondary current transformer (CT) input connections.

Q2: How should voltage monitoring be configured for isolated networks?
A2: Voltage monitoring must be configured as wye (phase-neutral) in isolated networks to prevent earth faults from causing false trip actions.

Q3: What power setting range is supported by the easYgen-3400-1-P1?
A3: The controller supports a wide setting range from 0.5 to 99,999.9 kW/kvar.

Sikeli (V/f)

Vector

mai amfani da wutar AC

  • Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
  • Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
  • Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
  • Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
  • Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.

Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.

Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.

Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

Duba bayanin samfur

TABBTAR DA INGANTACCEN AIKIN NA'URORI

Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.