Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:MPU50
369B1860G0026 GE MPU50 Processor 1.66GHz 1GB RAM
Manufacturer: General Electric
Product No.: MPU50
Product Type: Processor Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1200g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
GE MPU50 369B1860G0026 iDPU Module
GE MPU50 369B1860G0026 is an iDPU module with Intel 1.66 GHz 64-bit embedded processor. Features 1GB DDR2 memory and 2GB onboard non-volatile flash. Includes redundant 24V DC power inputs and 1Gbps redundant UDH and I/O networks. Weight: 1.2 kg (2.6 lbs).
Technical Specifications
| Parameter | Specification |
| Manufacturer | GE |
| Model | MPU50 369B1860G0026 |
| Product Type | iDPU Module |
| Processor | Intel 1.66 GHz 64-bit embedded |
| Memory | 1GB DDR2 667/800 MHz |
| Flash Memory | 2GB onboard non-volatile |
| Power Supply | Redundant 24V DC inputs, 15V 3A with power cord |
| UDH Control Network | 1Gbps redundant Ethernet |
| I/O Network | 1Gbps redundant Ethernet |
| Dual Tracking Network | 1Gbps dedicated |
| Serial I/O Bus | 4 smart high-speed redundant (1Mbps) |
| I/O Modules per Bus | 12 Nexus I/O modules |
| Maximum I/O Modules | 48 Nexus I/O modules |
| Operating System | QNX real-time multitasking |
| Cycle Time | 40ms fastest |
| Control Configuration Pages | 999 maximum |
| Clock Synchronization | NTP, ±1ms, SOE 1ms |
| Operating Temperature | 0°C to +60°C |
| Weight | 1.2 kg (2.6 lbs) |
Key Features
- Redundant 24V DC power inputs for high availability
- Intel 1.66 GHz 64-bit embedded processor
- 1GB DDR2 memory and 2GB non-volatile flash
- 1Gbps redundant UDH control and I/O networks
- 4 smart high-speed redundant serial I/O buses at 1Mbps
- Up to 48 Nexus I/O modules supported
- QNX real-time multitasking operating system
- Fastest 40ms cycle time
- NTP clock synchronization with ±1ms accuracy
Installation Guidelines (Field Engineer Notes)
Power Connection: Connect redundant 24V DC inputs to terminals. Use 2.5 mm² minimum wire. Module includes 15V 3A power cord. Verify both inputs for redundancy.
Network Configuration: Assign IP addresses for UDH control, I/O, and dual tracking networks. Use separate subnets for each network. Configure redundant network interfaces.
Serial I/O Bus: Each bus supports up to 12 Nexus I/O modules at 1Mbps. Terminate bus ends with 120Ω resistors. Maximum total modules is 48.
QNX Configuration: Operating system pre-installed. Application deployment via Ethernet. Use secure shell for remote access.
FAQs
Q1. What is the maximum number of I/O modules supported?
A1. The MPU50 supports up to 48 Nexus I/O modules across 4 serial I/O buses, with 12 modules per bus.
Q2. What is the cycle time of this module?
A2. The fastest cycle time is 40ms, configurable based on application requirements.
Q3. Does this module support redundant power inputs?
A3. Yes. The module features redundant 24V DC power inputs for high availability and fault tolerance.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...