Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:3500/15-03-03-01
3500/15-03-03-01 Bently Nevada Dual DC Supply 1.39kg
Manufacturer: Bently Nevada
Product No.: 3500/15-03-03-01
Product Type: Power Supply
Product Origin: USA
Payment:T/T, Western Union
Weight: 1390g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Bently Nevada 3500/15-03-03-01 Power Supply Module
Bently Nevada 3500/15-03-03-01 is a power supply module for the 3500 monitoring system. Features High Voltage DC (88-140V DC) in top slot and High Voltage DC (88-140V DC) in bottom slot. CSA / NRTL / C Class 1 Division 2 approved. Weight: 1.39 kg (3.1 lbs).
Technical Specifications
| Parameter | Specification |
| Manufacturer | Bently Nevada |
| Model | 3500/15-03-03-01 |
| Product Type | Power Supply Module |
| Top Slot Supply | High Voltage DC (88-140V DC) |
| Bottom Slot Supply | High Voltage DC (88-140V DC) |
| Agency Approval | CSA / NRTL / C (Class 1 Division 2) |
| Operating Temperature | -30°C to +65°C (-22°F to +150°F) |
| Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
| Humidity | 95% non-condensing |
| Dimensions (H x W x D) | 120.7 × 50.8 × 251.5 mm |
| Weight | 1.39 kg (3.1 lbs) |
Configuration Breakdown
| Code | Description |
| 03 | High Voltage DC (88-140V DC) - Top Slot |
| 03 | High Voltage DC (88-140V DC) - Bottom Slot |
| 01 | CSA / NRTL / C (Class 1 Division 2) |
Key Features
- Dual high-voltage DC power supplies for redundant operation
- CSA / NRTL / C Class 1 Division 2 certified for hazardous areas
- Wide operating temperature range -30°C to +65°C
- Provides regulated power to 3500 monitoring system rack
- Compact form factor for standard 3500 rack installation
Installation Guidelines (Field Engineer Notes)
Slot Placement: Top and bottom slots both require High Voltage DC supplies. Ensure both modules are properly seated and locked.
Wiring: Use 14 AWG minimum for DC input wiring. Connect positive to L1 and negative to L2. Torque terminals to 0.8 N·m (7 in·lb). Connect earth ground to chassis ground lug before energizing.
Voltage Verification: Measure incoming DC at the terminal block before inserting modules. Verify 88-140V DC between L1 and L2. Polarity must be correct.
Redundancy: Dual supplies provide hot-standby redundancy. If one supply fails, the second continues powering the rack without interruption.
Fuse Check: Each supply has internal fuses. Before replacing a module, check AC/DC input and fuse condition on the front panel.
FAQs
Q1. Can I mix AC and DC supplies in this configuration?
A1. No. This configuration uses High Voltage DC in both slots. Mixing AC and DC supplies requires a different part number with appropriate slot codes.
Q2. What is the maximum rack load for dual DC supplies?
A2. Each DC supply provides 2.5A maximum. Dual supplies share the load. Total rack current should not exceed 5A.
Q3. How do I test redundancy operation?
A3. Remove one supply while the rack is running. The second supply should maintain power with no interruption. Green LED on the remaining supply stays lit. Replace the removed supply within 30 seconds.
Download
Ƙarin ƙayyadaddun bayanai
- Shuɗi
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How to Break Data Silos for Bently Nevada Cloud Integration?
This article examines standardized cloud integration for Bently Nevada System1 vibration monitoring across heter...
-
ABB DCS Hot Swap Guide for Multi-Brand Plants
This technical guide delivers quantified hot swap procedures for ABB DCS and multi-brand redundant control systems. B...
-
Best Practices for Integrating AB PLCs with Emerson DCS?
Field‑tested solutions for integrating Allen‑Bradley PLCs with Emerson DCS. Quantifies efficiency losses, analyzes pr...
-
Why Are Isolated Plant Monitoring Systems Still Failing in 2026?
Most process plants still operate disconnected monitoring and control systems, missing subtle mechanical faults that ...
-
Can DeltaV Redundant DCS Eliminate Oil & Gas Shutdowns?
This article examines Emerson DeltaV DCS redundant architecture for oil and gas, presenting outage cost data, 1:1 red...
-
Why Are Legacy PLCs the Biggest Risk in New Energy Smart Factories?
This technical article examines how Allen‑Bradley Safety PLC resolves the safety-efficiency paradox in lithium batter...