Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:330907-05-30-70-02-CN
330907-05-30-70-02-CN Reverse Mount Probe Bently Nevada
Manufacturer: Bently Nevada
Product No.: 330907-05-30-70-02-CN
Product Type: Reverse Mount Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Bently Nevada 330907-05-30-70-02-CN is a 3300 NSv reverse mount eddy current probe for process compressor bearing and thrust position monitoring. The NSv platform raises chemical resistance over the 3300 RAM probe, and its side-view performance beats the 3000-series 190 probe at the same target gap. Factory DC resistance measures 5.9 ± 0.9 Ω across the 7.0 m (23.0 ft) cable, and the probe weighs roughly 14 to 150 g (0.5 to 5.3 oz) depending on case option.
Technical Specifications
| Parameter | Value |
|---|---|
| Model | 330907-05-30-70-02-CN |
| Probe Type | 3300 NSv Reverse Mount |
| Thread | M10 × 1 |
| Max Thread Engagement | 15 mm |
| Total Length | 7.0 m (23.0 ft) |
| Connector | Miniature ClickLoc Coaxial |
| DC Resistance (RPROBE) | 5.9 ± 0.9 Ω |
| Linear Range | 0.25 mm to 1.75 mm (10 to 70 mils), approx. -1 to -13 Vdc |
| Recommended Gap | 1.0 mm (40 mils) |
| Field Wiring | 0.2–1.5 mm² (16–24 AWG); 0.25–0.75 mm² (18–23 AWG) with ferrules |
| Max Cable Run | 305 m (1,000 ft) to monitor |
| Probe Tip Material | Polyphenylene Sulfide (PPS) |
| Probe Case Material | AISI 304 Stainless Steel |
| Probe Weight | Approx. 14–150 g (0.5–5.3 oz) |
| Case Torque | Max 22.6 N·m (200 in·lb), Recommended 7.5 N·m (66 in·lb) |
| Operating Temperature | -52 °C to +177 °C (-62 °F to +351 °F) |
| Storage Temperature | -52 °C to +177 °C (-62 °F to +351 °F) |
| Pressure Seal | Viton O-ring |
| Agency Approval | -CN (Country Specific) |
Installation Guide
Mount the probe through the bearing housing with the side-view tip aimed at the shaft surface, tightening to the recommended 7.5 N·m (66 in·lb) and never exceeding 22.6 N·m (200 in·lb). Set the gap at 1.0 mm (40 mils) and confirm the Proximitor output reads approximately -10 Vdc. Keep cable bend radius above 25 mm and route the ClickLoc connection clear of oil pooling. Use three-conductor shielded triad cable for field runs, with ferrules on 0.25–0.75 mm² conductors. For hazardous areas, wire the loop with the certified barriers required by the -CN approval. Avoid sustained exposure below -34 °C (-30 °F), which may cause premature pressure seal failure.
Engineering Advantages
The 3300 NSv probe carries higher chemical resistance than the 3300 RAM, suiting sour process compressor environments. Its side-view characteristics beat the 3000-series 190 probe when gapped at the same distance, giving cleaner signal in tight radial clearances. TipLoc molding locks the tip to the body, and gold-plated ClickLoc connectors stay seated under vibration. A probe weight of only 14 to 150 g (0.5 to 5.3 oz) adds minimal load to bearing housings, and the 305 m (1,000 ft) cable run gives flexible monitor cabinet placement. The -CN approval covers local hazardous area certification for Chinese refinery and power plant installations.
Technical FAQs
Q1: What gap voltage should I target at 1.0 mm?
A1: At a 1.0 mm (40 mil) gap, the Proximitor output reads approximately -10 Vdc near the center of the linear range. Verify against the monitor calibration curve for your system length.
Q2: What does the -CN suffix mean?
A2: -CN indicates Country Specific Approval, covering local hazardous area certification requirements for the destination market.
Q3: How much torque does the M10 reverse mount need?
A3: Tighten to the recommended 7.5 N·m (66 in·lb) and never exceed 22.6 N·m (200 in·lb) to avoid thread or case damage.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Do You Tune a 3500/92 Gateway for Stable Modbus TCP Polling?
This article explains why Bently Nevada 3500/92 Modbus TCP gateways fail in industrial control systems and how automa...
-
How Can You Prevent GE PLC Backup Failures?
This article explains why GE PLC backup failures occur in RX3i and VersaMax environments. It presents measured root c...
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...