Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:330101-00-36-10-01-05
330101-00-36-10-01-05 Bently Nevada 8mm Proximity Probe PPS
Manufacturer: Bently Nevada
Product No.: 330101-00-36-10-01-05
Product Type: 3300 XL 8 mm Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Bently Nevada 330101-00-36-10-01-05 3300 XL 8mm Proximity Probe
Product Overview
Bently Nevada 330101-00-36-10-01-05 is a 3300 XL 8mm proximity probe with PPS plastic encapsulation. Features patented CableLoc design with 330N pull strength. AISI 303/304 stainless steel case for corrosion resistance. Linear range 2mm starting at 0.25mm from target. Certified CSA, ATEX, and IECEx for hazardous locations.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| 1 3 | 330101 | 3300 XL 8mm Probe with armor |
| 4 | 00 | Unthreaded Length 0mm |
| 5 6 | 36 | Overall Case Length 36mm |
| 7 8 | 10 | Total Length 1.0 meter |
| 9 10 | 01 | Connector and cable type |
| 11 12 | 05 | CSA ATEX IECEx certified |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Bently Nevada |
| Model | 330101-00-36-10-01-05 |
| Type | 3300 XL 8mm Proximity Probe |
| Tip Material | Polyphenylene sulfide (PPS) |
| Case Material | AISI 303/304 SST |
| CableLoc Pull Strength | 330 N (75 lbf) |
| Linear Range | 2 mm (80 mils) |
| DC Resistance | 7.59 Ω ±0.50 |
| Capacitance | 69.9 pF/m |
| Total Length | 1.0 meter |
| Case Length | 36mm |
| Operating Temp Standard | 52°C to +177°C |
| Operating Temp Extended Tip | +218°C |
| Humidity Tolerance | < 3% ASF change at 93% RH |
| Accuracy ISF | ±5% |
| Certifications | CSA ATEX IECEx |
| FluidLoc | Prevents oil/liquid ingress |
| Field Wiring Max Length | 305 m (1,000 ft) |
| Field Wiring Gauge | 16 24 AWG |
| Weight | 323 g/m (11.4 oz) |
Installation
Mount probe with threaded case. Recommended gap setting for radial vibration is 9 VDC corresponding to approximately 1.27mm (50 mils). Use 3 conductor shielded triad cable for field wiring. Avoid prolonged exposure below 34°C. Maximum field wiring length 305 meters between Proximitor and monitor. Wire size 0.2 to 1.5 mm² (16 to 24 AWG).
Features
PPS tip provides 40% increased coil protection. CableLoc design withstands 330N pull strength. FluidLoc option prevents oil and liquid ingress. CSA, ATEX, and IECEx certified. ±5% ISF accuracy for reliable measurement.
FAQ
Q1: What is the recommended gap setting?
A1: 9 VDC equals approximately 1.27mm (50 mils) for optimal linear range in radial vibration monitoring.
Q2: What does the 05 certification option include?
A2: Option 05 provides CSA, ATEX, and IECEx hazardous location certifications for global installation compliance.
Q3: What is the maximum field wiring length?
A3: Maximum length is 305 meters (1000 feet) between Proximitor and monitor using 16 24 AWG shielded triad cable.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can DeltaV Redundant DCS Eliminate Oil & Gas Shutdowns?
This article examines Emerson DeltaV DCS redundant architecture for oil and gas, presenting outage cost data, 1:1 red...
-
Why Are Legacy PLCs the Biggest Risk in New Energy Smart Factories?
This technical article examines how Allen‑Bradley Safety PLC resolves the safety-efficiency paradox in lithium batter...
-
Can Bently Nevada + GE Fanuc PLC Prevent Mill Shutdowns?
This article examines Bently Nevada sensors integrated with GE Fanuc PLC for predictive maintenance in metallurgy. 20...
-
What Is the Data-Driven Strategy for Guaranteeing Genuine Control Spares?
Fragmented spare parts procurement causes 68% of unplanned plant shutdowns and inflates costs by 22% annually. This e...
-
Can GE Fanuc-Emerson Integration Cut OPEX 18%?
A regional refinery cut downtime 28% and energy use 18% via GE Fanuc PLC-Emerson DCS integration. Retained legacy har...
-
Why Do 78% of Digital Retrofits Fail Without Edge Data?
This technical article examines how Emerson's industrial edge gateway resolves multi-vendor OT interoperability chall...