Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:330101-00-30-10-02-05
330101-00-30-10-02-05 Eddy Current Probe Bently Nevada
Manufacturer: Bently Nevada
Product No.: 330101-00-30-10-02-05
Product Type: 3300 XL Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 160g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Bently Nevada 330101-00-30-10-02-05 3300 XL 8 mm Proximity Probe
The Bently Nevada 330101-00-30-10-02-05 is a premium 3300 XL series 8 mm proximity probe engineered for high-precision vibration, position, and oil film monitoring. Featuring a 3/8-24 UNF non-armored thread structure with a 3.0-inch case length, this eddy-current sensor delivers flawless peak-to-peak displacement measurements down to microscopic levels. Outfitted with a 1.0-meter integrated extension cable terminated in a ClickLoc miniature coaxial connector, it carries multi-agency hazardous area approvals (CSA, ATEX, IECEx Code 05) to operate safely near high-speed machinery.
Technical Specifications
| Brand / Manufacturer | Bently Nevada (Baker Hughes) |
| Complete Part Number | 330101-00-30-10-02-05 |
| Sensor Element Profile | 8 mm Tip Diameter (±0.1 mm accuracy envelope) |
| Thread Configuration | 3/8-24 UNF Thread Pattern | Non-armored design |
| Case & Unthreaded Metrics | Unthreaded Length: 0.0 in (Code 00) | Case Length: 3.0 in / 76.2 mm (Code 30) |
| Cable Length Allocation | 1.0 Meter / 3.3 Feet (Code 10) |
| Connector Interface | ClickLoc Miniature Coaxial Connector (Code 02) |
| Hazardous Area Compliance | CSA, ATEX, IECEx Certified | Intrinsic Safety & Non-Incendive (Approval Code 05) |
| Dynamic Vibration Range | ±2 mm (±0.08 inch) Peak-to-Peak linear measurement window |
| Thermal & Material Limits | Temp Range: -40°C to +120°C | 304 Stainless Steel Braided Shielded Cable |
| Product Net Weight | Approximately 0.16 kg (0.35 lbs) including integrated cable |
| System Compatibility | Bently Nevada 3300 and 3500 Machinery Monitoring Racks |
Quick Installation Guide
- Calculate your target mechanical gap using a calibrated voltmeter hooked to the Proximitor sensor output prior to securing the probe locking nut.
- Thread the lightweight 3/8-24 UNF probe body carefully into the machine bracket interface, confirming that the tip does not collide with the target shaft surface during manual rotation.
- Route the 1.0-meter 304 stainless steel braided cable back to the local junction housing, using protective conduit runs to shield it from pooling oils or heavy mechanical pinching.
- Snap the ClickLoc miniature coaxial interface cleanly into place inside the terminal hub, ensuring the connection remains perfectly dry and free from dust or grease contamination.
Technical FAQs
Q1: What does the "Code 05" designation signify regarding environmental and structural safety?
A1: The Code 05 designation certifies the hardware assembly meets global hazardous location criteria under CSA, ATEX, and IECEx standards. It allows the probe to be safely installed within Zone 0, Zone 1, or Division 1 industrial atmospheres when hooked to a properly matched, intrinsically safe 3300 XL Proximitor sensor barrier loop.
Q2: Why is the unthreaded length listed as 0.0 inches (Code 00) for this particular model layout?
A2: A 0.0-inch unthreaded designation means the external 3/8-24 threads run along the entire length of the 3.0-inch probe case. This maximizes configuration flexibility, allowing the probe to be deeply recessed or adjustably positioned through tight structural machine casings.
Q3: Can the ClickLoc connector interface be serviced or short-cut if the cable line needs to be modified?
A3: No. The ClickLoc coaxial fitting is precision-crimped at the factory to match targeted transmission resistance metrics. Shortening or altering the integrated 1.0-meter cable assembly shifts the intrinsic calibration curve of the eddy-current loop, causing false readings on your 3500 monitoring display.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How to Integrate Cross-Brand DCS and PLC?
This guide delivers field-verified engineering methods for integrating multi-brand DCS and PLC systems. It addresses ...
-
Can Genuine OEM Components Cut Your Automation Downtime by 90%?
This technical brief examines the financial and operational impact of non-genuine automation spare parts across ...
-
How to Solve PLC and DCS Faults in Industrial Automation?
Unplanned downtime in manufacturing is frequently traced to failures in PLC, DCS, and TSI systems, costing medium-siz...
-
How Does ABB System 800xA Enable Cost-Effective DCS Modernization?
This technical article examines a hybrid multi-brand DCS retrofit strategy centered on ABB System 800xA for petrochem...
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
