Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:330101-00-12-15-02-05
330101-00-12-15-02-05 Bently Nevada 8mm Proximity Probe
Manufacturer: Bently Nevada
Product No.: 330101-00-12-15-02-05
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Bently Nevada 3300 XL 8 mm Proximity Probe (330101-00-12-15-02-05)
The Bently Nevada 330101-00-12-15-02-05 is a high-precision 3300 XL 8 mm eddy current proximity probe designed for reliable vibration monitoring and shaft position measurement in industrial machinery. Built in the USA with a 3/8-24 UNF threaded AISI 303/304 stainless steel case, this unarmored model features a 0.0-inch unthreaded length, a 1.2-inch overall case length, and a 1.5-meter (4.9 feet) standard cable with a miniature coaxial ClickLoc connector. Weighing approximately 323 g/m (11.4 oz), it utilizes patented TipLoc tip molding and CableLoc technology to provide 330 N (75 lbf) pull strength. It comes complete with CSA, ATEX, and IECEx hazardous area approvals (05 option).
Key Performance Advantages
Features a Polyphenylene Sulfide (PPS) tip for high mechanical and chemical durability, a nominal probe DC resistance of 7.73 ± 0.50 Ω, and an 80 mil (2 mm) linear range starting at 0.25 mm (10 mils) from the target. The probe supports differential pressure sealing up to 5 bar via a Viton® O-ring and operates effectively in temperatures ranging from -52°C to +177°C (-62°F to +350°F).
Technical Specifications
| Manufacturer & Series | Bently Nevada / Baker Hughes (3300 XL 8 mm Series) |
| Part / Ordering Number | 330101-00-12-15-02-05 |
| Thread & Case Dimensions | 3/8-24 UNF Thread / 0.0 in Unthreaded / 1.2 in Case Length |
| Cable Length & Connector | 1.5 Meter (4.9 ft) Standard Cable / ClickLoc Coaxial (Unarmored) |
| Linear Range & Scale Factor | 2 mm (80 mils) Linear Range / 7.87 V/mm (200 mV/mil) ±5% (ISF) |
| Weight & DC Resistance | Approx. 323 g/m (11.4 oz) / 7.73 ± 0.50 Ω Resistance |
| Operating Temperature | Standard: -52°C to +177°C (-62°F to +350°F) |
| Agency Approvals | 05 Option: CSA, ATEX, IECEx Hazardous Location Approvals |
Installation & Maintenance Guidelines
- Probe Mounting & Gap Setting: Thread the 1.2-inch probe case directly into machine bearing housings. Set the mechanical initial gap to approximately -9 Vdc [1.27 mm (50 mils)] from the target surface to position the probe in the center of its linear range.
- Cable Protection: Route the 1.5-meter unarmored cable through conduit or secure mounting channels to protect against sharp bends or mechanical pinching. Avoid exposing the cable to temperatures below -34°C (-30°F) to prevent premature pressure seal wear.
- System Integration: Connect the ClickLoc coaxial connector securely to compatible 3300 XL extension cables and Proximitor® sensors, ensuring total matched system length (e.g., 5-meter or 9-meter systems).
Frequently Asked Questions
Q1: Has EMC filter?
A1: N/A (sensor probe).
Q2: Key feature vs PF523?
A2: ClickLoc & CableLoc tech.
Q3: Drives 3-phase motors?
A3: No, measures vibration.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can GE Fanuc PLC + Emerson DCS Cut Your Plant Upgrade Costs?
This article examines a data-proven retrofit strategy combining GE Fanuc PLC and Emerson DeltaV DCS for legacy indust...
-
Why Bently Nevada Bridges Process Control and Machine Health?
Unobserved mechanical vibration remains a critical blind spot in modern factory automation, causing up to 8% annual r...
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
